KLD806 Rs485 Flange Mounting Silo Radar Level Sensor PTFE Antenna

Price Negotiable
Price: Negotiable
MOQ: 1PCS
Delivery Time: 5-8 work days
Brand: KACISE
Product Description

KLD806 80G FM Radar Level Sensor

Introduction

Radar level sensor antenna emits and narrow microwave pulse. This pulse propagates in space at the speed of light. When it encounters the surface of the measured medium, part of its energy is reflected back and received by the same antenna. The time interval between the transmitted pulse and the received pulse is proportional to the distance from the antenna to the surface of the measured medium.

Feature

 

The best choice for applications with high range dust, strong dust and dust adhesion.

80G continuous frequency modulation wave measurement has better penetrability to high dust environment;

  •        Mature tracking algorithm makes the tracking of dust level more stable, and can easily cope with high-range cement, carbon powder, vegetation ash and other scenarios;
  •        The unique measurement algorithm can penetrate the powder dust attached to the antenna surface, and the signal is not easy to be blocked.

  

 

KLD806

 

 

Medium: solid, storage container, process container,

strong dust application

Measuring range: 0.3m~10/20/30/60/100m

Process connection: flange ≥ DN100

Process temperature: -40~110℃

Process pressure: -0.1~0.3MPa

Antenna size: 76mm lens antenna (purge optional)

Antenna material: PTFE

Accuracy: ±5mm

Protection class: IP67

Center frequency: 80GHz

Launch angle: 3°

Power supply: two-wire /DC24V

four-wire /DC12~24V

four-wire /AC220V

Casing: aluminum/plastic/stainless steel

Signal output: two-wire /4...20mA/HART protocol

four-wire 4...20mA/ RS485 Modbus

 

Dimensions

 

 

Installation

1.Flange Installation
When using flange installation, the minimum distance between the instrument and the tank wall should be 200mm.
datum plane
vessel center or axis of symmetry
  
 
2.Hoisting Installation
    
 

Installation Requirements

 

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.


           

 

Under extremely complex working conditions, the instrument can work normally if there is no obstacle in the area with a radius of 20cm centered on the installation point.

 

Installation connection diagram:

The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle.

Too long installation connection will affect the radar performance.

 

 

Dimensions

Casing Dimension
Unit in mm:

 

Production:

 

Xi'an Kacise Optronics Tech Co., Ltd considers itself a solution provider and manufacturer. We offer maximum flexibility and a cost-optimised offer for our OEM customers.
What we could provide:
The range includes customized shell version/color, thread type(G-Thread/NPT Thread), Customized Software, prints, manual and catalog. If you are interested in installing at your side, Radar Module is available for sure.

 

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.