Revolutionary Clamp-on Ultrasonic Flowmeter Power Supply 10-24V VDC
Introduction
The KUF100 ultrasonic flowmeter operates using the time difference method. It sends and receives ultrasonic signals through the fluid and calculates the flow rate by measuring the difference in the propagation time of these signals in the downstream and upstream directions. This method enables precise measurement of fluids with suspended particles or bubbles and is not influenced by the fluid's conductivity.
Feature
- Simple installation and convenient operation. There is no need to break the pipe or stop for a long time for construction, and the installation can be easily completed within a few minutes.
- It adopts a new clamp-on design without touching the measuring medium. It can avoid pressure loss and medium pollution caused by traditional flowmeters.
- A variety of modes can be set, flexible and diverse.
- A set of machines can be used for all diameters within the measuring range, and is suitable for various metal pipes and resin pipes.
- Super large screen display. The display content is diverse and man-machine friendly.
- It can be selected as an ultrasonic cold (heat) meter to realize the monitoring and measurement of energy consumption.
Technical Specifications
| Supported Pipe Materials | stainless steel, iron, brass, aluminum, PVC, PP, PVDF and other rigid plastic pipes |
| Supported Liquid Medium | Water or other (single without solid particles and impurities) |
| Supported Medium Temperature | 0-75°C (no freezing on the surface, high temp, version customizable) |
| Default Low Flow Cutoff | 0.1m/s |
| Display Method | 256*128 backlit LCD |
| Response Time | 0.5~60s |
| Accuracy Class | ±2%, up to ±1% after calibration |
| Data Storage Period | 300 milliseconds |
| Memory Backup | EEPROM (data storage length: more than 10 years, data read/write frequency: more than 1 million times) |
| Power And I/O Connectors | M12 aviation plug |
| Output | 4-20mA |
| Communication | Modbus RS485 |
| Optional Output | OCT (pulse output) / one relay alarm |
| Power Supply | 10-24V VDC |
| Electric Power | <3W |
| Circuit Protection | Power reverse protection, power surge protection |
| Each output short-circuit protection, each output surge protection | |
| Protection Level | IP65 |
| Ambient Temperature | -10 to 60°C (no freezing) |
| Relative Humidity | 35 to 85% RH (non-condensing) |
| Vibration Resistance | 10 to 55 Hz, double amplitude 1.5mm, 2 hours each for XYZ axes |
| Impact Resistance | 100m/s2 16 ms pulse, X, Y, Z axis each 1000 times |
| Meter Material | aluminum alloy, industrial plastic |
| Cable Length | Standard 2 meters, (PT1000 standard 9 meters) |
Flow Range
| Pipe diameter | Upper limit flow value ( L/min ) |
| 15 | 60 L/min |
| 20 | 100 L/min |
| 25 | 200 L/min |
| 32 | 300 L/min |
| 40 | 400 L/min |
| 50 | 600 L/min |
| 65 | 1000 L/min |
Tip: The inner diameter of the smallest measurable pipe section is greater than or equal to 12mm.
Dimensions
DN15-40
DN50-65
Ultrasonic Cold (Heat) Meter
Ordering Information
| Code | Definition |
| Pipe diameter: DN15-DN65mm | |
| Range: 0.03m/s-10m/s | |
| Accuracy: ±2% (1% after calibration) | |
| Measurement medium: water/other (single without solid particles and impurities) | |
| Power supply: 10~24VDC/1A | |
| Sensor operating temperature: 0-115℃; | |
| Other: 2 meters of cable as standard | |
| Heat meter: with a pair of PT1000 temperature sensors; one end of the temperature sensor is on the meter, and the other end of the cable is standard 9m | |
| Pipe Diameter | |
| S | DN15-DN40 |
| T | DN50-DN65 |
| Meter Type | |
| 1 | Ultrasonic flow meter |
| 2 | Ultrasonic cold (heat) meter |
| Sensor Type | |
| C2 | 0-65°C |
| C2U | 0-115°C |
| Output (can choose two out of four) | |
| A | 4-20mA |
| M | Modbus |
| O | OCT (Frequency) |
| R | 1 Relay |
| PT1000 Temperature Sensor Cable Length | |
| P | Temperature sensor cable length at the other end 9m |
| P(15) | Temperature sensor cable length at the other end 15m |
| P(25) | Temperature sensor cable length at the other end 25m |
Example:
- KUF100-S-1-C2-AM
ultrasonic flowmeter, range DN15-DN40, temp. range 0-65℃, with 4-20mA and RS485 output, standard cable length 2m.
- KUF100-S-2-C2U-AM-P
ultrasonic cold (hot) meter, range DN15-DN40, temp. range 0-115℃, with 4-20mA and RS485 output, standard cable length 2m; with a pair of PT1000 temperature sensors; one end of the temperature sensor is on the meter, and the other end of the cable is standard 9m
Appendix:
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.


