KGD - YQ - 506 Online Monitoring System for Ship Exhaust Carbon Emissions
Product Introduction
The KGD - YQ - 506 system is based on advanced domestic sensor technology combined with the desulfurization tower process. By adding carbon monitoring and temperature - pressure - flow modules, it can monitor parameters such as SO₂, CO₂, CH₄, N₂O, and flow rate in ship exhaust in real - time. It can directly conduct the detection of sulfur content in the exhaust gas of the desulfurization tower and the work related to greenhouse gases, providing high - quality data support for the EU MRV monitoring report and the subsequent carbon trading market.
Product Features
- The sensor technology is fully self - developed. With years of in - depth industry experience, the system has stable performance.
- The sampling flow path is heated at high temperature throughout the process, and anti - corrosion materials and treatment processes are adopted to adapt to the highly humid and corrosive environment during shipping.
- The analysis mainframe uses an electrically - tuned analysis module with excellent shock - resistance. The design without mechanical moving parts ensures good shock - resistance.
- Extractive measurement is adopted, which is not affected by dust, temperature, and pressure fluctuations in the flue.
- An automatic correction algorithm is built - in to eliminate the interference of other gas components.
Technical Parameters
| Indicator | Parameter Details for SO₂ | Parameter Details for CO₂ | Parameter Details for N₂O | Parameter Details for CH₄ |
| Measured Components (Exhaust Gas Components) | SO₂ | CO₂ | N₂O | CH₄ |
| Measurement Principle | UV - DOAS/NDIR/GFC/TDLAS | UV - DOAS/NDIR/GFC/TDLAS | UV - DOAS/NDIR/GFC/TDLAS | UV - DOAS/NDIR/GFC/TDLAS |
| Measuring Range | 0 - 500 ppm | 0 - 25% | 0 - 100 ppm | 0 - 100 ppm |
| Resolution | 0.1 ppm | 0.01% | 0.1 ppm | 0.1 ppm |
| Measurement Accuracy | ±2% F.S. | |||
| Repeatability | ≤±1% | |||
| Pressure Range (Exhaust Gas Parameters) | -10 - 10 kPa | |||
| Temperature Range | -20 - 480 °C | |||
| Flow Rate Range | 0 - 40 m/s | |||
| Flow Rate Accuracy | ≤2.0% F.S. (Additional measuring channels can be added for higher accuracy) | |||
| Power Supply Requirements | AC 220V ±10%, Frequency: 50/60Hz | AC 220V ±10%, Frequency: 50/60Hz | AC 220V ±10%, Frequency: 50/60Hz | AC 220V ±10%, Frequency: 50/60Hz |