KUS-W80 Underwater Distance Sensor with 200kHz Transducer Frequency, Low No-load Current, and IP68 Protection for Underwater Ranging

Price Negotiable
Price: Negotiable
MOQ: 1PCS
Delivery Time: 5-8 work days
Brand: KACISE
Product Description
KUS-W80 Underwater Distance Sensor
1. Introduction

The single-beam underwater ultrasonic ranging sensor is a high-response ranging sensor designed based on the ARM architecture.

The sensor has a built-in RS485 chip to read data and configure internal parameters. The internal parameters can be modified through the ModBus-RTU protocol to adjust the performance of the sensor and implement certain functions.

2. Measurement principle

During the distance measurement process, the ultrasonic signal is emitted by the ultrasonic probe, reflected by the liquid or other solid medium, and then reflected by the same probe. The time difference between the ultrasonic emission and reception is measured to achieve the level measurement. The relationship between the sound wave transmission distance L, the sound velocity v and the sound wave transmission time t can be expressed by the formula:

Ultrasonic distance measurement formula

L: The distance between the ultrasonic probe and the measured material surface. Unit: m;

v: The sound velocity value after temperature compensation. Unit: m/s;

t: The running time of the sound wave within the measurement range. Unit: s

3. Features
  • Protection level: IP68
  • Equipped with RS485 communication, data can be read and written
  • Address, baud rate, and other corresponding parameters can be modified through ModBus-RTU protocol;
  • Short response time
  • Temperature compensation
4. Application
  • Underwater position and distance detection
  • Underwater robot obstacle avoidance and collision detection
  • Underwater gate switch status monitoring
  • Tank water level monitoring
  • Unmanned boat application
5. Technical Parameters
Electrical characteristics
Working voltage 10.8V~26.4VDC, reverse polarity protection
No-load current ≤15mA
Voltage drop ≤ 2.5V
Start-up delay <2000ms (software delay for protection)
Output characteristics
Output type Standard RS485 output (Modbus-RTU protocol)
Rated working current Ie ≤100mA, short circuit/overload protection
Repeatability accuracy ±0.25%
Accuracy ±0.5%
Ambient temperature
Working temperature -20~60℃
Storage temperature -20~60℃
Mechanical characteristics
Output connection method 4-core outlet
Output line length Default 2 meters (other line lengths need to be customized)
Protection level IP68
Material Casing: ABS, PC

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.