Dwyer MS Series Magnesense Differential Pressure Transmitter with 4-20 mA Output and Field-Selectable Ranges
Price:
Negotiable
MOQ:
1PCS
Delivery Time:
5-8 work days
Brand:
Dwyer
Product Description
Dwyer MS Series Magnesense Differential Pressure Transmitter
The Dwyer MS Series Magnesense Differential Pressure Transmitter combines versatility and precision for industrial pressure and air velocity monitoring. Leveraging patented magnetic sensing technology, this transmitter delivers long-term reliability with field-selectable ranges, adjustable outputs, and optional LCD displays—making it an ideal single solution for diverse pressure and flow applications.
Applications
HVAC Systems:
- Filter pressure drop monitoring
- Air velocity measurement with Pitot tubes
- Duct static pressure control
- Blower vacuum sensing
- Cleanroom positive pressure maintenance
- Fluid amplifier pressure monitoring
- Room pressure differential control
- Fire damper position indication
Model Specifications
| Model | Description |
|---|---|
| MS-021 | Differential pressure transmitter, 4-20 mA output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount. |
| MS-021-LCD | Differential pressure transmitter, 4-20 mA output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD. |
| MS-111 | Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount. |
| MS-111-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD. |
| MS-112 | Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount. |
| MS-112-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD. |
| MS-121 | Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount. |
| MS-121-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD. |
| MS-122 | Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount. |
| MS-122-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD. |
| MS-131 | Differential pressure transmitter, 4-20 mA output, selectable range 10" w.c. (2 kPa), wall mount. |
| MS-131-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 10" w.c. (2 kPa), wall mount, with LCD. |
| MS-141 | Differential pressure transmitter, 4-20 mA output, selectable range 15" w.c. (3 kPa), wall mount. |
| MS-141-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 15" w.c. (3 kPa), wall mount, with LCD. |
| MS-151 | Differential pressure transmitter, 4-20 mA output, selectable range 25" w.c. (5 kPa), wall mount. |
| MS-151-LCD | Differential pressure transmitter, 4-20 mA output, selectable range 25" w.c. (5 kPa), wall mount, with LCD. |
| MS-221 | Differential pressure transmitter, 0-10 V output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount. |
| MS-221-LCD | Differential pressure transmitter, 0-10 V output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD. |
| MS-311 | Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount. |
| MS-311-LCD | Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD. |
| MS-312 | Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount. |
| MS-312-LCD | Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD. |
| MS-321 | Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount. |
| MS-321-LCD | Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD. |
| MS-322 | Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount. |
| MS-322-LCD | Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD. |
| MS-621 | Differential pressure transmitter, 5 VDC output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount. |
| MS-621-LCD | Differential pressure transmitter, 5 VDC output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD. |
| MS-711 | Differential pressure transmitter, 5 VDC output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount. |
| MS-711-LCD | Differential pressure transmitter, 5 VDC output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD. |
| MS-712-LCD | Differential pressure transmitter, 5V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD. |
| MS-721 | Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount. |
| MS-721-LCD | Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD. |
| MS-722-LCD | Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD. |
| MS-821 | Differential pressure transmitter, 5V output, 12V input, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount. |
| MS-821-LCD | Differential pressure transmitter, 5V output, 12V input, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD. |
| MS-911 | Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount. |
| MS-911-LCD | Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD. |
| MS-912 | Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount. |
| MS-912-LCD | MS-912 Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD. |
| MS-921 | Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount. |
| MS-921-LCD | Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD. |
| MS-922 | Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount. |
| MS-922-LCD | Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD. |
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Kacise Optronics Co.,Ltd.
Location
2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person
Evelyn Wang