FLOWSIC100 Flare-XT ultrasonic flow measurement instrument
Price:
Negotiable
MOQ:
1PCS
Delivery Time:
5-8 work days
Brand:
Endress+Hauser
Product Description
FLOWSIC100 Flare-XT Ultrasonic Flow Measurement Instrument
Advanced ultrasonic flow measurement instrument designed for demanding industrial applications including flare gas measurement, steam flow monitoring, and process optimization.
Key Specifications
| Measured Variables | Mass flow rate, volumetric flow (standard condition), volumetric flow (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity |
| Measuring Range | 0.03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s) |
| Conformities | ATEX: 2014/34/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU, PED: 2014/68/EU |
Applications
- Detection of flare gas leaks and steam flow measurement
- Monitoring of gas losses and steam injection in flare gas burning
- Process optimization and predictive maintenance
- Flare gas measurement for natural gas production and processing
- Flare gas measurement in chemical and petrochemical plants
- Measurement of LNG boil-off gas
Device Features
- Reliable measurement at high gas velocities and changing gas compositions
- Direct mass flow calculation without additional gas analyzers
- Intuitive FLOWgate™ software for commissioning, operation and diagnostics
- Self-monitoring, self-testing and predictive maintenance capabilities
Key Benefits
- Compliance with multiple standards and guidelines for flare gas measurement
- Maximum plant availability and operational reliability
- Compatibility with current and future communication architectures
- Independent maintenance with verification on demand
- Easy replacement of existing measurement systems with retrofit solutions
Technical Details
| Measuring Principle | Ultrasonic transit time difference measurement |
| Max. Measurement Error |
Volumetric flow, a.c.: 1% ... 5% (≥ 0.3 m/s) Mass flow rate a.c.: 2% ... 5.5% (≥ 0.3 m/s) With spool piece and flow calibration: 0.5% ... 2% |
| Medium Temperature Range | -196 °C ... +280 °C (-320 °F ... +536 °F) |
| Operating Pressure Range | Up to 20 bar(g) depending on device flange and certification |
| Nominal Pipe Size | 1-path: 4″ ... 86″, 2-path: 12″ ... 86″ |
Hazardous Area Approvals
Comprehensive certifications for Interface Unit and Sensors including IECEx, ATEX, and NEC/CEC approvals for Zone 1, Zone 2, and Division 1/2 applications with various gas groups and temperature classes.
Outputs & Communication
| Analog Outputs | Up to 6 outputs (16-bit, 4-20 mA), galvanically isolated, NAMUR NE43 compliant |
| Digital Outputs | Switching outputs (70 mA max) and frequency outputs (10 kHz max) |
| Digital Communication | HART, MODBUS, FOUNDATION FIELDBUS |
Related Videos