FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

Price Negotiable
Price: Negotiable
MOQ: 1PCS
Delivery Time: 5-8 work days
Brand: Endress+Hauser
Product Description
FLOWSIC100 Flare-XT Ultrasonic Flow Measurement Instrument
Advanced ultrasonic flow measurement instrument designed for demanding industrial applications including flare gas measurement, steam flow monitoring, and process optimization.
Key Specifications
Measured Variables Mass flow rate, volumetric flow (standard condition), volumetric flow (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Measuring Range 0.03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
Conformities ATEX: 2014/34/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU, PED: 2014/68/EU
Applications
  • Detection of flare gas leaks and steam flow measurement
  • Monitoring of gas losses and steam injection in flare gas burning
  • Process optimization and predictive maintenance
  • Flare gas measurement for natural gas production and processing
  • Flare gas measurement in chemical and petrochemical plants
  • Measurement of LNG boil-off gas
Device Features
  • Reliable measurement at high gas velocities and changing gas compositions
  • Direct mass flow calculation without additional gas analyzers
  • Intuitive FLOWgate™ software for commissioning, operation and diagnostics
  • Self-monitoring, self-testing and predictive maintenance capabilities
Key Benefits
  • Compliance with multiple standards and guidelines for flare gas measurement
  • Maximum plant availability and operational reliability
  • Compatibility with current and future communication architectures
  • Independent maintenance with verification on demand
  • Easy replacement of existing measurement systems with retrofit solutions
Technical Details
Measuring Principle Ultrasonic transit time difference measurement
Max. Measurement Error Volumetric flow, a.c.: 1% ... 5% (≥ 0.3 m/s)
Mass flow rate a.c.: 2% ... 5.5% (≥ 0.3 m/s)
With spool piece and flow calibration: 0.5% ... 2%
Medium Temperature Range -196 °C ... +280 °C (-320 °F ... +536 °F)
Operating Pressure Range Up to 20 bar(g) depending on device flange and certification
Nominal Pipe Size 1-path: 4″ ... 86″, 2-path: 12″ ... 86″
Hazardous Area Approvals
Comprehensive certifications for Interface Unit and Sensors including IECEx, ATEX, and NEC/CEC approvals for Zone 1, Zone 2, and Division 1/2 applications with various gas groups and temperature classes.
Outputs & Communication
Analog Outputs Up to 6 outputs (16-bit, 4-20 mA), galvanically isolated, NAMUR NE43 compliant
Digital Outputs Switching outputs (70 mA max) and frequency outputs (10 kHz max)
Digital Communication HART, MODBUS, FOUNDATION FIELDBUS

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.