Proline Promag W 400 electromagnetic flowmeter
Price:
Negotiable
MOQ:
1PCS
Delivery Time:
5-8 work days
Brand:
Endress+Hauser
Product Description
Proline Promag W 400 Electromagnetic Flowmeter
Versatile standard flowmeter for the water and wastewater industry. Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss. Ideal for water measurement applications including drinking water, utility water, and industrial/municipal wastewater.
Field of Application
With international approvals for custody transfer and drinking water applications, the Promag W serves a broad variety of uses. Available in both compact and remote versions, the Promag W 400 saves time and costs with transmitter functionality optimized for Water & Wastewater applications. Heartbeat Technology enables measurement reliability and compliant verification.
Key Features
- Bidirectional measuring principle virtually independent of pressure, density, temperature and viscosity
- Ideal for water measurement applications
- International drinking water approvals
- IP68 protection (Type 6P enclosure)
- Custody transfer approval to MI-001/OIML R49
- Transmitter housing in durable polycarbonate or aluminum
- WLAN access capability
- Integrated data logger for measured values monitoring
Key Benefits
Reliable Performance: Constant accuracy with 0 x DN inlet run and no pressure loss
Flexible Engineering: Sensors with fixed or lap-joint process connections
Application Fitness: EN ISO 12944 corrosion protection for underground or underwater installation
Improved Availability: Sensor compliance with industry-specific requirements
Safe Operation: No need to open device with touch control display
Time-Saving Operation: Local operation without additional software/hardware via integrated web server
Integrated Verification: Heartbeat Technology with build-up detection
Technical Specifications
| Measuring Principle | Electromagnetic |
| Nominal Diameter Range | DN 25 to 3000 (1 to 120") |
| Measured Variables | Volume flow, conductivity, mass flow |
| Maximum Measurement Error |
Volume flow (standard): ±0.5% o.r. ±1 mm/s (0.04 in/s) Volume flow (option): ±0.2% o.r. ±2 mm/s (0.08 in/s), Flat Spec |
| Measuring Range | 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d) |
| Maximum Process Pressure | PN 40, Class 300, 20K |
| Medium Temperature Range |
Hard rubber liner: 0 to +80°C (+32 to +176°F) Polyurethane liner: -20 to +50°C (-4 to +122°F) PTFE liner: -20 to +90°C (-4 to +194°F) |
| Wetted Materials | Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum |
| Degree of Protection |
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control, configuration via display, web browser, and operating tools |
| Power Supply | AC 100-240 V / AC/DC 24 V |
Approvals and Certifications
- Hazardous area: cCSAus
- Metrological: Calibration per ISO/IEC 17025, NAMUR, Custody transfer MI-001/OIML R49
- Pressure: CRN
- Material: 3.1 material certificates
- Hygienic: Drinking water approvals including ACS, KTW-BWGL, NSF 61, WRAS BS 6920
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Kacise Optronics Co.,Ltd.
Location
2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person
Evelyn Wang