Proline Prosonic Flow B 200 ultrasonic flowmeter

Price Negotiable
Price: Negotiable
MOQ: 1PCS
Delivery Time: 5-8 work days
Brand: Endress+Hauser
Product Description
Proline Prosonic Flow B 200 Ultrasonic Flowmeter
The Proline Prosonic Flow B 200 is a specialized ultrasonic flowmeter designed for accurate and reliable measurement of wet biogas and digester gas, even under fluctuating process conditions.
Key Innovation
With unique integrated real-time methane fraction analysis, this device enables continuous measurement and monitoring of gas flow as well as gas quality. The measuring principle is unaffected by gas composition.
Field of Application
Inline flowmeter specifically designed for wet biogas and digester gas measurement under fluctuating process conditions. Enables efficient process control, energy balancing, and ensures compliance and process safety through Heartbeat Technology.
Key Benefits
  • Integrated real-time methane fraction measurement
  • Optimized for low pressure gas with specialized sensor design
  • No additional pressure loss - full bore design
  • Enhanced process transparency through diagnostic capability
  • Convenient device wiring with separate connection compartment
  • Safe operation - no need to open device due to display with touch control and background lighting
  • Integrated verification via Heartbeat Technology
Technical Specifications
Measuring Principle
Ultrasonic flow measurement
Device Properties
  • Multivariable device: flow, temperature and methane
  • Loop-powered technology
  • Robust dual-compartment housing
  • Worldwide approvals for plant safety
Performance Specifications
Parameter Specification
Measuring Range (Standard) 1 to 30 m/s (3.28 to 98.4 ft/s)
Measuring Range (Option) 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Medium Temperature Range 0 to +80 °C (+32 to +176 °F)
Maximum Process Pressure 11 bar a (159 psi a)
Process Pressure Range 0.7 to 11 bar a (10.2 to 159 psi a)
Measurement Accuracy
Volume Flow Type Accuracy
Standard Volume Flow ±1.5% o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
±3% o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Optional Volume Flow ±0.1% o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
±1.5% o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
Nominal Diameter Range
  • Single-path version: DN 50 (2"), DN 80 (3")
  • Two-path version: DN 100 to 200 (4 to 8")
Measured Variables
Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature
Wetted Materials
  • Sensor: 1.4404/1.4435 (316L)
  • Transducer: HNBR
  • Temperature sensor (option): AFM 34
Environmental Specifications
Parameter Specification
Ambient Temperature (Carbon Steel) -10 to +60 °C (+14 to +140 °F)
Ambient Temperature (Stainless Steel) -40 to +60 °C (-40 to +140 °F)
Transmitter Housing Material AlSi10Mg, coated; 1.4404 (316L)
Degree of Protection IP66/67, type 4X enclosure
Electrical Specifications
Component Specification
Display/Operation 4-line backlit display with touch control (operation from outside)
Outputs 4-20 mA HART (passive), 4-20 mA (passive), Pulse/frequency/switch output (passive)
Inputs Current input 4-20 mA (passive)
Digital Communication HART
Power Supply Multiple configurations: DC 12-35V, DC 12-30V, DC 9-32V depending on output type
Certifications and Approvals
  • Hazardous Area: ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN, EAC
  • Metrological: Calibration performed on accredited facilities (ISO/IEC 17025)
  • Pressure: PED
  • Material: 3.1 material certificates (wetted parts)

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.