Intelligent Digital Signal Output 6GHz Radar Water Level Meter
Explosion-Proof 6G Intelligent Radar Sensor Liquid Level Meter Measuring Instrument
Product Introduction
The 6G radar level gauge is designed for liquid, paste, granule, and block material level measurement using non-contact technology. It is particularly suitable for applications with significant temperature and pressure variations, as well as environments containing inert gases and volatile substances. Utilizing microwave pulse measurement technology, this instrument operates effectively within the industrial frequency band range. The beam energy is low, allowing safe installation on various metal and non-metal containers or pipes without harm to human health or the environment.
Operation Principle
This product employs intelligent self-tuning echo tracking technology for non-contact measurement. It features micro-fit waveguide technology design and ultra-wideband echo trace capture/emission energy regulation and control technology to ensure measurement stability and pulse conditioning. The antenna design utilizes a total gain of 23dB with a half-power beamwidth of approximately 8.5°.
Key Features
- Non-contact measurement technology
- High precision, stability, and reliability
- Long operational lifespan
- Compact structure with excellent environmental adaptability
- No periodic recalibration or maintenance required
- Easy installation process
Technical Specifications
KLD601 Model
| Parameter |
Specification |
| Suitable Medium |
Liquid, slightly corrosive liquid |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
20m |
| Aerials |
The Rod Antenna (PP/PTFE) |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 130) ℃ |
| Measurement Precision |
±10mm |
| Process Pressure |
(-0.1 ~ 0.3) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Flange (optional) / Thread |
KLD602 Model
| Parameter |
Specification |
| Suitable Medium |
Liquid, especially for corrosive liquid |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
20m |
| Aerials |
The Rod Antenna (PTFE) |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 180) ℃ |
| Measurement Precision |
±10mm |
| Process Pressure |
(-0.1 ~ 4) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Flange (optional) |
KLD603 Model
| Parameter |
Specification |
| Suitable Medium |
Liquid, especially with pressure and volatile liquid |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
35m |
| Aerials |
The Horn Antenna |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 250) ℃ |
| Measurement Precision |
±10mm |
| Process Pressure |
(-0.1 ~ 4) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Flange (optional) |
KLD604 Model
| Parameter |
Specification |
| Suitable Medium |
Solid particles or block material (not suitable for solid powder) |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
35m |
| Aerials |
The Horn Antenna |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 250) ℃ |
| Measurement Precision |
±20mm |
| Process Pressure |
(-0.1 ~ 0.1) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Cardan Flange (optional) |
KLD605 Model
| Parameter |
Specification |
| Suitable Medium |
Liquid, especially suitable for low dielectric constant, sticky, with mixing liquid |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
20m |
| Aerials |
The Horn Antenna |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 400) ℃ |
| Measurement Precision |
±10mm |
| Process Pressure |
(-0.1 ~ 4) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Flange (optional) |
KLD606 Model
| Parameter |
Specification |
| Suitable Medium |
Solid, especially suitable for high temperature conditions |
| Explosion-proof Grade |
Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range |
15m |
| Aerials |
The Horn Antenna |
| Frequency |
6GHz |
| Temperature |
(-40 ~ 400) ℃ |
| Measurement Precision |
±20mm |
| Process Pressure |
(-0.1 ~ 0.1) MPa |
| Signal Output |
(4 ~ 20) mA/HART |
| Scene Display |
Four LCD/can be programmed |
| Power Source |
Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability |
±1mm |
| Casing |
Aluminum/Plastic |
| Connection |
Flange (optional) |
Our Services
- Your inquiry will be replied within 24 hours
- Well-trained and experienced staff to answer all your enquiries in fluent English
- OEM & ODM services - we can help design and implement your product requests
- Distributorship offered for your unique designs and select current models
- Protection of your sales area, design ideas, and all private information
- Volume discounts based on order quantities
- Paid repair services for meter damages not arising from manufacturing quality issues or outside warranty scope