This is an intelligent digital displayed product for pressure test and control. It has a complete electronic structure. Oil-filled piezo-restive pressure sensor with diaphragm is applied in the front part. The processed signals control two switches then to test & control the pressure. With flexible application, easy debugging and high reliability, this product is widely used applied to test & control the pressure of fluid medium in many industries including areas of hydroelectricity, city water, oil, chemical, machinery hydraulic system etc.
 

Parameter

 

Pressure range -0.1~0~100MPa Accuracy 0.5%F.S.
Over load 200% Pressure type Gauge
Liability ≤0.1% /year Power 24VDC or 220VAC
Display 0.56" LED Display range -1999~9999

 

Response time

 

<30ms

Ambient

temperature

-20℃~70℃
Relative humidity ≤80% Wetted part SS304
 

 

Installation

 

1.Mechanical connection

 

It can be directly mounted in the hydraulic pipe by the connecting thread. In critical application, such as server vibration or shock, soft hose is recommended to use.

 

 

2.Electrical connection

 

To avoid electromagnetic interference, please know

 

a.the cable system should be as short as possible

 

b.To use shielded wire

 

c.To keep way from any interference resources, for example, electric appliances and devices, if installed by soft hose, its body should be grounded independently.

 

 

Setting

 

 

AL1H: Switch connection point for switch 1(when pressure reaches this value, indicator on) AL1F: Switch connection point for switch 1(when pressure reaches this value, indicator off) AL2H: Switch connection point for switch 2(when pressure reaches this value, indicator on) AL2F: Switch connection point for switch 2(when pressure reaches this value, indicator off)

FILT: Filter coefficient. To avoid digit display from fluctuating which is caused by pressure change, after 3-10seconds, it can be set END then save then exit. The bigger the filter coefficient is, the more stable it is, but the more hysteric.

 

Note:

 

Switching points are determined by the configuration of the present connection and disconnection value.

When connection value is higher than disconnection value, it is called upper-limit alarm output (normally open status);

When connection value is lower than disconnection value, it is called lower-limit alarm output (normally close status);

The deviation between connection and disconnection value is the return difference for the switch point.

 

 

Example (How to finish the settings as following)

  • Set switch point 1 at upper-limit alarm output(normally open status),connect at 4Mpa and disconnection when lower than 3.95Mpa,response delay is 3 seconds
  • Set switch point 2 at lower-limit alarm output(normally close status),connect at 10Mpa and disconnection when lower than 9.95Mpa,response delay is 10 seconds

 

Enter the menu: Set AL1H=4.00 AL1F=3.95 AL2H=9.95 AL2F=10.00

  • Press “SET”
  • “LOCK” sign(remind you to key in password,0001)
  • Press ▲ or ▼ to key in the password
  • Press “SET” to confirm

 

 

  • Press ▲ or ▼as page up or page down to select (AL1H, AL1F, AL2H, AL2F, END)
  • Press “SET” to enter selection menu
  • Press ▲or ▼ to alter the settings
  • Press “SET” to confirm, or press ▲or▼to enter other menus for other settings

 

Workshop

 


 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.