Wall Mount Inline Carbon Steel Ultrasonic Flow Meter For DN15mm - DN6000mm Pipe
KUFS2000 Series Wall Mount Ultrasonic Flow Meter
1.Introduction
The KUFS2000A2 flow meter is consist of the main unit and inline ultrasonic sensor.single liquid can trasmit sound wave.such as water,sea water,sewage,oil chemicals,alcohol,etc. IP68 protection level.measuring temperature range -30ºC~160ºC.
It can be installed on the wall or in instrument box,protecction grade is IP67.Suitable for pipe sizes from DN 15mm to DN6000mm.
2. Features
- High accuracy:1%
- High reliability,Use low voltage. Anti-interference is high.
- Suitable diameter:Choose different types of sensors, you can realize the diameters of DN15~DN6000mm tube measurement channel flow.
- Use double-balanced signal to launch and receive circuit, It can resist inverter, television tower, high tension cable, etc.
- Powerful Recording Function
- Automatically record the following data:Record the totality data of the last 512 days/ 128 months/ 10 years.
- The time and corresponding flow rate of the last 64 times of power on and off events. Record the working status of the last 32 days.
- Support heat measuring:It can measure heat if add temperature sensor.
- Support SD memorizer:Optional SD memorizer function, which can remember a large of data.
3. Installation
1. Clamp on type
Easy to install without interrupt fluid, no damage for pressure
Install and service clamp sensor conveniently
It can measure the temperature out of the pipe, compute the quantity of heat
2. Plug in type
Easy to install without interrupt fluid, no damage for pressure
Stable operation, contact the temperature sensor which inserted, compute quantity of heat by the
temperature sensor.
3. Pipe type
Install with interrupt flow
High accuracy, stable operation, contact the temperature sensor which inserted, compute quantity of heat
by the temperature sensor
4.Sensor selection
Sensor selection depend on the application field parameters such as the diameter of the pipe the fix method
the kind of the flow, please refer to the fix method choice chapter for details.
Working Condition
| Main Unit | Sensor | |
| Protection | IP67 | IP68 |
| Humidity | ≤85%RH | |
| Temperature | -20~60℃ | -30~160℃ |
Basic Parameters
| Accuracy | ±1% |
| Velocity Range | 0~±10m/s, Bi-directional measurement |
| Pipe Size | DN15~DN6000 |
| Temperature | - 30~160℃ |
| Type of Liquid |
Single liquid can transmit sound wave. such as water, sea water, sewage, oil, chemicals , alcohol, etc |
| Pipe Material |
Carbon steel, stainless steel 304, stainless steel 316. Flange standard GB/T9119-2000, GB/T81-94 |
| Signal Output |
1 way 4-20mA output(impedance 0~1K, accuracy 0.1%) 1 way OCT pulse output( Pulse width 6 ~ 1000ms) 1 way relay output |
| Signal Input |
3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor. |
| Interface | RS485, support MODBUS |
| Data Storage | SD card regularly store the pre-set results (optional) |
| Power Supply | DC8~36V or AC85~264V |

Get in Touch