26GHz Frequency Fluid Level Meter IP67 Protection For Strong Corrosive Liquid
26G Radar level sensor for all kinds of strong corrosive liquid, strong acid strong base chemical liquid container, bin
Product Overview
This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 80 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.
Principle
Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).
- The characteristics of 26G radar level meter:
1) Small antenna size, easy to install; Non-contact radar, no wear, no pollution.
2) Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.
3) Serious dust environment on the high level meter work has little effect.
4) A shorter wavelength, the reflection of solid surface inclination is better.
5) Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.
6) The measuring range is smaller, for a measurement will yield good results.
7) High signal-to-noise ratio, the level fluctuation state can obtain better performance.
8) High frequency, measurement of solid and low dielectric constant of the best choice.
Parameters
| Suitable for Medium | Strongly corrosive liquid |
| Application | HCl, H2SO4, HF and strong base in tank, etc. |
| Measuring Range | 10m |
| Process Connection | Flange, Min. flange is DN80 |
| Medium Temperature | -40 ~ 120 ℃ |
| Process Pressure | -0.1 ~ 0.1MPa |
| Accuracy | ±5~10mm |
| Protection Grade | IP67 |
| Frequency Range | 26GHz |
| Explosion-proof Grade | Exia IICT6 Gb |
| The signal Output | 4 ~ 20mA/HART(2 wire/4wire),RS485/Modbus is optional |
The Electrical Connection
The power supply voltage:
| (4~20)mA/HART (Two wire system) The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument. |
| (4~20)mA/HART(Four wire system) Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data. |
| RS485 / Modbus Power supply and Modbus signal line separate drespectively using a two-core shielded cable, the power supply voltage range see technical data. |
Applications and Cases:
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.