1. Parameter

General specifications

Sensing range 100... 1000 mm
Adjustment range  
Unusable area 0 ... 100 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx.220 kHz
Response delay approx. 50 ms

 

Indicators/operating means

 

LED blue power-on

 

LED yellow

indication of the switching state

flashing: program function object detected

 

LED red

permanently red: Error Red,flashing:program function,object not detected

Electrical specifications

Operating voltage UB 15 ... 30 V DC , ripple 10 %SS
No-load supply current I0 ≤ 45 mA

Input

Input type 1 TEACH-IN input

operating range A1: -UB ... +1 V, operating range A2: +6 V ...

+UB

input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

Output

Output type 1 switch output E4, NPN NO/NC,programmable
Rated operating current Ie 200 mA , short-circuit/overload protected
Default setting Switching point A1:70mm Switching point A2: 800mm
Voltage drop ≤ 2.5 V
Repeat accuracy ≤1 %
Switching frequency f ≤ 13 Hz
Range hysteresis H 2 % of the set operating distance
Temperature influence ±1.5% of full-scale value

Ambient conditions

Ambient temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)

Mechanical specifications

Connection V1 connector(M12×1),4-pin
Protection degree IP67
Material Housing brass, nickel-plated
Transducer

epoxy resin/hollow glass sphere mixture;

foam polyurethane, cover PBT

2. Dimensions

3. Electronic interface and signals definition


4. Description of Sensor Functions

Adjust the paramater

The ultrasonic sensor is equipped with a switch output featuring two teachable switching points. To set these points, the supply voltage, either -UB or +UB, needs to be applied to the TEACH-IN input. During this process, LEDs provide feedback, indicating whether the sensor has successfully recognized the target. Switching point A1 is configured using -UB, while A2 is set with +UB. The sensor offers the flexibility of eight different output functions.

 

It's important to note that the switching point and setting distance can only be adjusted after the power is turned on. The internal clock ensures that changes cannot be made after 5 minutes of power-on time. If there's a need to modify the switching point, the user must set the desired distance after restarting the power. This ensures a clear and controlled adjustment process for the sensor's configuration.

 

TEACH-IN window mode, normally-open function

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

- Set target to far switching point

- TEACH-IN switching point A2 with + UB

TEACH-IN window mode, normally-closed function

- Set target to far switching point

- TEACH-IN switching point A2 with - UB

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

TEACH-IN switching point, normally-open function

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

- Cover sensor with hand or remove all objects

from sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN switching point, normally-closed function

- Cover sensor with hand or remove all

objects from sensing range

- TEACH-IN switching point A2 with - UB

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

TEAC-IN large hysteresis interval, normally-open mode

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

- Set target to far switching point

- TEACH-IN switching point A2 with - UB

TEAC-IN large hysteresis interval, normally-closed mode

- Set target to far switching point

- TEACH-IN switching point A2 with + UB

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

TEACH-IN detection of objects presence normally open mode

- Cover sensor with hand or remove all objects from

sensing range

- TEACH-IN switching point A2 with - UB

- Cover sensor with hand or remove all objects from

sensing range

- TEACH-IN switching point A2 with + UB

TEACH-IN detection of objects presence normally closed mode

- Cover sensor with hand or remove all objects from sensing range

- TEACH-IN switching point A2 with +UB

- Cover sensor with hand or remove all objects from sensing range

- TEACH-IN switching point A2 with -UB

Default setting of switching point

A1=blind range,A2=nominal distance

 

 

LED displays
Displays in dependence on operating mode Red LED Yellow LED

TEACH-IN switching point

Object detected

No object detected

Object uncertain(TEACH-IN invalid)

 

 

off flashes On

 

 

flashes off

off

Normal operation off Switching state
Fault on Previous state

 

 

5. Installation conditions

 

If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Kacise Optronics Co.,Ltd.
Location 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
Contact Person Evelyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.