Inverter High Precision PCB Mount Hall Current Transducer
PCB Mount Hall Effect Current Transducer Hall Effect Dc Current Sensor
TBC-LSR508 series current sensor is closed loop device based on the measuring principle of the hall effect,with a galvanic isolation between primary and secondary circuit. It has strong anti-jamming ability and provides accurate electronic measurement of DC, AC or pulsed currents.
|
Electrical data(Ta=25℃±5℃) |
|
Type |
TBC06 |
TBC10 |
TBC15 |
TBC20 |
TBC25 |
TBC30 |
TBC32 |
TBC40 |
TBC50 |
Unit |
|
Rated input (Ipn) |
6 | 10 | 15 | 20 | 25 | 30 | 32 | 40 | 50 | A |
|
Measuring ran(Ip) |
±15 | ±25 | ±37.5 | ±50 | ±62.5 | ±75 | ±80 | ±100 | ±125 | A |
|
Turns (Np/Ns) |
1:1200 | 1:1000 | 1:1125 | 1:1000 | 1:1250 | 1:1125 | 1:1200 | 1:1000 | 1:1000 | T |
| Internal resister | 40.0 | 20.0 | 15.0 | 10.0 | 10.0 | 7.5 | 7.5 | 5.0 | 4.0 | Ω |
|
Rated output |
@ Ip=±Ipn ±0.8±0.5% | V | ||||||||
|
Output rsistance |
≤20 | Ω | ||||||||
|
Size of primary pins |
□ 6.28 ×1.0 | mm | ||||||||
|
Supply voltage |
+5±5% | V | ||||||||
|
Power consumption |
≤15+Ip/Ns | mA | ||||||||
|
Reference voltage |
+2.5±0.5%(Output) | V | ||||||||
|
Vrefinternal resist resistor |
200 | Ω | ||||||||
|
Vref external range resistor |
2.0-2.8(Input) | V | ||||||||
| Zero voltage | @ Ip=0 +2.5±0.5% | V | ||||||||
|
Offset drift |
@ -40~+105℃ ≤±0.05 | mV/℃ | ||||||||
| output drift | @ -40~+105℃ ≤±0.05 | mV/℃ | ||||||||
|
Linearity |
@ Ip=0-±Ipn ≤0.1 | %FS | ||||||||
|
Total accuracy |
≤±1.0 | % | ||||||||
|
di/dt |
>50 | A/µS | ||||||||
|
Response time |
@ Ip=Ipn, 50 A/µS ,10%-90% <1.0 | µS | ||||||||
|
Bandwidth |
@ -1db DC~100 | KHZ | ||||||||
|
Galvanic isolation |
@ 50HZ,AC,1min 3.0 | KV | ||||||||
Applications
Variable speed drives
Photovoltaic
Frequency converter
Electrochemical
Electric machine control
| Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
| Directions for use |
When the current will be measured goes through a sensor ,the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output voltage available.
Standards
- UL94-V0.
- EN60947-1:2004
- IEC60950-1:2001
- EN50178:1998
- SJ 20790-2000
| General date |
| Value | Unit | Symbol | |
| Operating temperature | -40 to +85 | ºC | TA |
| Storage temperature | -40 to +125 | ºC | TS |
| Mass(approx) | 12 | g | M |
| Characteristics chart |
Pulse current signal response characteristic Effects of impulse noise
Get in Touch