Shenzhen YuanTe Technology Co., Ltd. (Safegas)
                                                                                                           
Verified Supplier
16 Years
Since 2010
Menu

SKY2000 Portable Gas Detector for PH3 Fumigation Residual with 0–20ppm Range, 0.01ppm Resolution, and Electrochemical Sensor

Price Negotiable
Price: negotiable
MOQ: 1
Delivery Time: 3 working days
Brand: Safegas
Product Description
SKY2000 Portable Gas Detector for PH3 Fumigation Residual with 0–20ppm Range
Short Description

A fast-response, high-accuracy handheld gas detector with built-in sampling pump, designed for phosphine (PH₃) fumigation residual monitoring. Measures from 0–20ppm with 0.01ppm resolution using an electrochemical sensor. Features Ex ia IIC T4 Ga explosion-proof certification, IP66 protection, 100 hours runtime (pump off), and triple alarm (sound, light, vibration). Essential for fumigation safety in grain storage, tobacco, timber, and container inspection.

Product Overview

The SKY2000 series is a portable, pump-suction gas detector designed for fast response and high accuracy. With an internal sampling pump, it actively draws air for immediate analysis – ideal for spot-checking fumigated spaces. The unit is housed in high-intensity engineering plastic, making it suitable for harsh environments.

Taking phosphine (PH₃) as an example – a common fumigant for grain, tobacco, and timber – the SKY2000 detects residual concentrations from 0–20ppm with a fine 0.01ppm resolution, ensuring safe re-entry and compliance with occupational exposure limits. The detector supports span calibration and zero calibration for reliable readings, plus a one-key factory reset. Data logging is optional (up to 100,000 readings) and can be exported to a PC via USB without additional software.

Why Detect Phosphine (PH₃) in Fumigation?
What is Phosphine (PH₃)?

Phosphine is a highly toxic, colorless, flammable gas with a distinctive odor of garlic or decaying fish. It is widely used as a fumigant to control insects and rodents in:

Industry Application
Grain storage Silos, warehouses, shipping containers (wheat, corn, rice, barley)
Tobacco Cured tobacco leaves and finished products
Timber & wood products Wood-boring insect control
Food processing Dried fruits, nuts, spices, animal feed
Empty cargo containers Preventing cross-contamination
Museums & archives Insect pest control in artifacts


Why Monitor Residual PH₃ After Fumigation?

Even after aeration, dangerous residual PH₃ can remain in confined spaces (deep grain piles, container corners, under tarpaulins). Monitoring ensures worker safety before re-entry.

Concentration (ppm) Health Impact
0.3 ppm OSHA PEL (8-hour TWA)
1.0 ppm NIOSH recommended exposure limit (15 min ceiling)
3 ppm Immediate eye/nose irritation, headache, nausea
10 ppm Severe respiratory distress, pulmonary edema
20 ppm Life-threatening; can be fatal with short exposure
200–400 ppm Rapid unconsciousness and death (IDLH = 50 ppm)

Key Fact: PH₃ has no cumulative effect in the body, but acute exposure can be fatal. Its odor threshold (~0.5–1 ppm) is higher than the safe exposure limit, meaning you cannot rely on smell alone – a detector is essential.

Where SKY2000 is used for PH₃ detection:
  • Grain silos and warehouses – Post-fumigation clearance testing
  • Shipping containers – Before opening after fumigation
  • Tobacco curing barns – Worker safety during handling
  • Timber treatment facilities – Residual gas monitoring
  • Food processing plants – After pest control treatments
  • Quarantine and border inspection – Container gas analysis
  • Museums and archives – After artifact fumigation
  • Emergency response – Leak detection during fumigant application
Product Pictures

Key Technical Specifications (for PH₃, 0–20ppm)
Parameter Value
Gas Detected Phosphine (PH₃) – also supports CO, H₂S, O₂, LEL, and hundreds of other gases
Detection Principle Electrochemical
Measuring Range 0 – 20 ppm
Resolution 0.01 ppm
Precision ≤ ±1–5% FS (depending on gas)
Response Time (T90) ≤20 seconds
Repeatability ≤ ±1%
Zero Shift ≤ ±1% (FS/year)
Linearity Error ≤ ±1%
Recovery Time ≤10 seconds
Display LCD dot matrix display with backlight
Gas Unit Switchable (ppm, mg/m³)
Operating Language Chinese / English
Data Logging Optional – 100,000 readings, export to PC via USB (no software needed)
Sampling Method Built-in pump (active suction)
Alarm Mode Sound (buzzer), light (flashing LED), vibration
Explosion-Proof Grade Ex ia IIC T4 Ga
Protection Grade IP66
Operating Temperature -20°C to +50°C
Operating Humidity 0–95% RH
Operating Time 100 hours (pump off)
Dimensions 205 × 75 × 32 mm
Weight 300 g
Main Features
  • Built-in sampling pump – Fast air intake, ideal for spot-checking fumigated containers and grain silos.
  • High accuracy for low-level PH₃ – 0.01ppm resolution detects residual concentrations below OSHA PEL (0.3 ppm).
  • Electrochemical sensor – Specifically optimized for PH₃ detection with good stability.
  • Explosion-proof certified – Ex ia IIC T4 Ga for use in potentially explosive fumigation environments (PH₃ is flammable).
  • Rugged and portable – IP66 dust/water resistant, high-strength plastic housing, weighs only 300g.
  • Flexible calibration – Span and zero calibration functions for reliable long-term performance.
  • One-key factory reset – Quickly restore default settings.
  • USB data export – Optional 100,000-record logging; export to PC without drivers or software.
  • Triple alarm system – Audible, visual (flashing LED), and vibration alarms – crucial in noisy industrial environments.
  • Long battery life – 100 hours continuous operation with pump off; pump on reduces runtime but still adequate for a full work shift.
  • Switchable gas units – ppm / mg/m³ easily toggled.
Typical Applications for PH₃ Fumigation Residual Detection

The SKY2000 is the industry standard for post-fumigation safety testing:

  • 1. Grain Silos and Bulk Storage
    • After aeration, test residual PH₃ at various depths using the pump with a long probe
    • Ensure levels are below 0.3 ppm before workers enter
    • Re-test after turning grain or during out-loading
  • 2. Shipping Containers (Fumigated)
    • Containers fumigated with PH₃ for export/import quarantine
    • Test before opening – residual gas can accumulate in sealed boxes
    • Typical test: insert probe through door seal or specially designed port
  • 3. Tobacco Warehouses
    • Phosphine used to control beetle and tobacco moth
    • Monitor during aeration and before handling cured leaves
  • 4. Timber and Wood Treatment
    • Fumigation of logs, lumber, and finished wood products to kill wood-boring insects
    • Test inside stacks and under covers
  • 5. Food Processing Facilities
    • Flour mills, rice mills, nut processing plants, spice grinding operations
    • After pest control fumigation, test production areas, conveyors, and bins
  • 6. Container Inspection at Ports/Borders
    • Quarantine officers use SKY2000 to screen arriving containers for residual PH₃
    • Prevents worker exposure during unloading
  • 7. Empty Cargo Containers
    • Some empty containers carry residual PH₃ from previous fumigated cargo
    • Test before reuse or repair
  • 8. Museums and Archives
    • Artifacts and documents fumigated with PH₃ for insect control
    • Test display cases and storage rooms before handling sensitive materials
  • 9. Grain Transport Holds (Ships, Railcars)
    • Test railcars and ship holds after fumigation and before loading/unloading
  • 10. Emergency Leak Response
    • Detect accidental release during fumigant application (e.g., aluminum phosphide tablets in water)
    • Monitor perimeter and evacuation zones


Company Introduction

Shenzhen YuanTe Technology Co., Ltd. (brand: Safegas) was established in 2010 and specializes in the R&D, manufacturing, and sales of gas detection equipment and integrated systems. With over 16 years of industry expertise, the company serves sectors including grain storage, fumigation, oil & gas, chemicals, environmental protection, and municipal engineering. Their product portfolio includes portable gas detectors, fixed gas transmitters, gas analyzers, control panels, and calibration accessories. All products are manufactured under ISO9001 and ISO45001 management systems, holding international certifications such as IECEx, ATEX, and EMC. With an annual production capacity of over 80,000 units, YuanTe Technology supplies gas detection solutions to customers worldwide.

Company Advantages
  • Established since 2010 – Over 16 years of experience in gas detection R&D and manufacturing.

  • Full product range – Portable detectors, fixed transmitters, analyzers, control panels, and accessories.

  • International certifications – IECEx, ATEX, EMC certified for hazardous areas (including coal mines).

  • Wide gas & industry coverage – Hundreds of gases, serving oil & gas, chemical, mining, environmental, food, pharma, and more.

  • Strong R&D & quality – ISO9001 & ISO45001 certified, with a professional R&D team and global service network.

  • High production capacity – Over 80,000 units per year with fast delivery (5–7 working days typical).

  • Global customer support – 24/7 after-sales service and solutions tailored to diverse industries.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Location 4F, BLDG B, GAOCHUANGDE INDUSTRIAL PARK, NO.7, SANHE ROAD, DALANG, LONGHUA DISTRICT, SHENZHEN
Contact Person Cloris Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.