Chinese Ball Valve Butterfly Valve and Auma SQ Series Part-turn Actuators with AM Actuators Control Unit
The AUMA SQ/SQR 05.2 – 14.2 part-turn actuators with AUMA MATIC AM 01.1 / AMExC 01.1 controls in SFC version are purpose-built for safety instrumented systems (SIS) per IEC 61508 / IEC 61511. These quarter-turn actuators provide certified “Safe end position feedback" using mechanical limit switches, achieving SIL 2/3 capability in low-demand mode. The compact design integrates actuator, worm gear, and controls into a single weatherproof unit, ensuring reliable 90° valve positioning with comprehensive diagnostics for proof testing and PVST.
- Certified Functional Safety: Safe end position signaling via direct-wired mechanical switches; exida-validated PFDavg and SFF values.
- Proof Test Ready: Dedicated checklist for verifying safe end position signal, collective fault output, and dynamic response.
- Partial Valve Stroke Test (PVST): Programmable diagnostics for frequent, non-disruptive verification of actuator and valve health.
- Self-Locking Mechanism: Prevents unintended valve movement from standstill; suitable for all standard output speeds.
- Robust Safety Architecture: HFT = 0, type A device classification, wide ambient range with optional double sealing.
- Local & Remote Diagnostics: Mechanical position indicator, collective fault contact, and reaction monitoring support.
| Parameter | Details |
|---|---|
| Safety Function | Safe end position feedback (mechanical) |
| SIL Capability | SIL 2/3 (low demand mode) |
| Proof Test Coverage (PTC) | 90 % recommended |
| Torque Range | 50 – 2,400 Nm |
| Enclosure | IP68 (8 m water / 96 h) |
| Ambient Temperature | –40 °C to +80 °C |
| Type of Duty | S2-15/30 min, S4-25/50 % |
| Valve Attachment | EN ISO 5211 F05–F16 |
Designed for safety-critical quarter-turn valves in emergency shutdown (ESD), fire & gas, and high-integrity pressure protection systems (HIPPS) in refineries, chemical plants, and power stations. The SFC version ensures compliance with functional safety standards while maintaining standard open-close operation.
- What is the “Safe end position feedback" function? Direct-wired limit switches signal when the actuator reaches the commanded end position; only this path is safety-related.
- How often should PVST be performed? At least 10* more frequently than the full proof test to maintain diagnostic coverage.
- Can I extend the proof test interval? Yes, with appropriate scaling rules and regular lubrication checks (max. 10 years).
- Is manual operation allowed in safety mode? Yes, but motor operation has priority; document any manual intervention.
- What if a fault is detected during maintenance? Immediately report to AUMA; re-validate the safety function after repair.
Phone/WeChat/WhatsApp: +8613916209596
Email: svetama@gbsxj.com
- AUMA SQEx explosion-proof part-turn actuators
- AUMA SA multi-turn actuators with AM controls
- AUMA AC 01.2 advanced controls (higher diagnostics)
- Torque measurement flange DMF
- Spring-return actuators for fail-safe duty