Chinese Gate Globe Valve Body AUMA SA Multi-turn Electric Control Valve Actuators with AC Actuator Control Unit
The AUMA SA .2 series multi-turn actuators with AUMATIC AC 01.2 controls in SFC (Safety Figure Calculated) version are certified for use in safety instrumented systems (SIS) according to IEC 61508 / IEC 61511. They provide the “Safe end position feedback” safety function with proven SIL capability up to SIL 2/3 (low demand mode). The system combines reliable mechanical torque and limit switching with advanced diagnostics and EtherNet/IP communication, ensuring safe and monitored valve operation in critical applications.
- Functional Safety Certified: Safe end position feedback via mechanical switches; SIL 2/3 capability with calculated PFDavg and SFF values.
- Proof Test Support: Partial Valve Stroke Test (PVST) and full proof test procedures for regular verification.
- EMERGENCY Operation: Programmable reaction (stop, open, close, or intermediate position) with bypass options for torque and thermal protection.
- Comprehensive Diagnostics: Reaction monitoring, torque characteristics, operating data logging, and NAMUR NE 107 status signals.
- Self-Locking Design: Prevents uncontrolled valve movement from standstill up to maximum torque (for standard speeds).
- Robust for Safety Use: Wide temperature range, IP68 protection, and optional double-sealed terminal compartment.
| Parameter | Details |
|---|---|
| Safety Function | Safe end position feedback (mechanical switches) |
| SIL Capability | Up to SIL 2/3 (low demand mode) |
| Proof Test Interval | User-defined (typically 1–5 years) |
| Torque Range | 10–1,000 Nm |
| Output Speeds | 4–180 rpm (50 Hz) |
| Enclosure Protection | IP68 (8 m / 96 h) |
| Ambient Temperature | –50 °C to +80 °C |
| Communication | EtherNet/IP with safety-related status signals |
| Lifetime | 20,000–25,000 cycles (depending on size) |
Designed for safety-critical valve automation in oil & gas, chemical, power, and nuclear plants where emergency shutdown (ESD) or safety instrumented functions are required. Suitable for gate/globe valves in high-integrity pressure protection systems (HIPPS) and fire/gas detection loops.
- How often must I perform a proof test? Interval depends on PFDavg target; typically annual or every 2–5 years – see exida report for guidance.
- What is the safe end position feedback? Mechanical limit switches signal end position; hysteresis is minimal but must be considered in loop design.
- Can I use PVST for partial testing? Yes, programmable direction, stroke, and time; does not replace full proof test.
- Is the actuator suitable for high-demand mode? Only safe end position feedback under specific conditions; consult manual for limitations.
- How to verify SIL compliance? Use the provided exida report and perform site-specific verification per IEC 61511.
Phone/WeChat/WhatsApp:
+8613916209596
Email: svetama@gbsxj.com
- AUMA SAEx .2 explosion-proof actuators for hazardous areas
- AC 01.2 controls with Profibus or Foundation Fieldbus
- Torque measurement flange DMF for enhanced diagnostics
- Spring-return SAR .2 actuators for fail-safe applications
- AUMA CDT commissioning software for safety validation