Oil and Gas Industry Pneumatic Valve Positioner Fish-er DVC2000 DVC6200 and FOXBORO Controller and Spirax Sarco Valve KE73 and Actuator PN9223E
The Fish-er FIELDVUE DVC6200 is a high-performance digital valve controller that converts a 4-20 mA control signal into pneumatic output for accurate valve positioning. It supports HART communication for setup, monitoring, and diagnostics, helping operations stay closer to setpoint for better process control and product quality. Available in aluminum or stainless steel, it works with single- or double-acting actuators in linear or rotary applications.
- Linkageless feedback using contactless Hall-Effect technology with stem/shaft-mounted magnet array for reliable, low-maintenance positioning.
- Advanced diagnostics via ValveLink software or AMS, including travel history, pressure readings, and valve performance insights.
- One-button setup and calibration for quick commissioning.
- Low air consumption with optional low-bleed relay to reduce operating costs.
- Integral pressure sensors for real-time monitoring of supply, output, and actuator pressures.
- SIL 3 capable (HART version when input is 0 mA/0 VDC) for safety-critical uses.
- Modular design with options for hazardous area certifications.
| Communication Protocol | 4-20 mA HART (HART 5 or HART 7 selectable) |
| Input Signal | 4-20 mA DC, nominal; minimum voltage 9.5 V DC for analog control, 10 V DC for HART |
| Supply Pressure | Minimum recommended 0.3 bar / 5 psig above actuator requirements; maximum 10.0 bar / 145 psig |
| Output Signal | Pneumatic up to full supply pressure; minimum span 0.4 bar / 6 psig, maximum span 9.5 bar / 140 psig |
| Steady-State Air Consumption (standard relay) | <0.38 Nm³/h / 14 scfh at 1.4 bar / 20 psig; <1.3 Nm³/h / 49 scfh at 5.5 bar / 80 psig |
| Low Bleed Relay | Average 0.056 Nm³/h / 2.1 scfh at 1.4 bar; 0.184 Nm³/h / 6.9 scfh at 5.5 bar |
| Maximum Output Capacity | 10.0 Nm³/h / 375 scfh at 1.4 bar; 29.5 Nm³/h / 1100 scfh at 5.5 bar |
| Operating Temperature | -40 to +85 °C / -40 to +185 °F (standard); -52 to +85 °C / -62 to +185 °F with fluorosilicone elastomers |
| Enclosure Protection | IP66/Type 4X |
| Housing Materials | Low-copper aluminum (standard) or stainless steel (optional) |
| Mounting | Integral to Fish-er 657/667/GX actuators; compliant with IEC 60534-6-1/-6-2, VDI/VDE 3845, NAMUR; remote-mount options available |
| Certifications | Explosion Proof, Intrinsically Safe, Non-incendive, Flame Proof (CSA, FM, ATEX, IECEx) |
Widely used for control valve positioning in oil & gas, refining, chemical processing, power generation, and pulp & paper industries—especially where diagnostics help reduce unplanned downtime and improve loop performance.
- Q: How does it handle diagnostics?
- A: It uses built-in pressure sensors and travel data for predictive insights via ValveLink or AMS software.
- Q: Is linkage required?
- A: No—linkageless design uses magnetic feedback for most setups.
- Q: What about air usage?
- A: Standard relay is low consumption; low-bleed option further reduces it for efficiency.
- Q: Can it be used in hazardous areas?
- A: Yes, with approvals for explosion-proof, intrinsically safe, and other classifications.
- Q: What's the temperature range?
- A: -40 to +85 °C standard; down to -52 °C with extreme temperature elastomers.
Email: tracychen@gbsxj.com
WhatsApp: +8617799852698
Phone/wechat: 13032169170
Consider the DVC6200 SIS for safety instrumented systems, or the DVC6200f/P for FOUNDATION fieldbus/PROFIBUS PA protocols.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.