Single core and three cores cu/XLPE/CTS/STA/PVCpower cable rated voltage 6/10(12)kV

 

Detailed Product Description

 

Certificates

CE, SGS, KEMA and more others at request

 

Standards:

International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.2-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request

 

Applications

Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.

Rated voltage: 6/10 kV

 

Construction

Conductor: Plain annealed stranded compacted circular copper or aluminium conductor to IEC60228 class 2
Conductor Screen:Extruded semi-conductive compound

Insulation:XLPE (cross-linked polyethylene) rated at 90°C

Insulaton Screen:Extruded semi-conductive compound
Metallic Screen:copper tape or a concentric layer of copper wires
Colour for core indentification:Red,Yellow ,Blue tape shall be applied between insulation screen and metallic screen ( The above identifying can be changed as order)
Assembly : Three screened cores are laid up together ,if necessary filled with non hygroscopic material compatible with insulation and covered with a layer of PVC sheath
Inner Sheath:Extruded layer of PVC ST2 or PE , LSZH
Armour: Double of galvanized steel tape or galvanized steel wire for three core power cable ,Double of aluminium tape or aluminium wire for single power cable
Outer Sheath: PVC type ST2 to IEC 60502 or PE ,LSZH

 

Technical data

Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.

Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%

 

Technical Specifications

 

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness of Copper Strip Thickness of steel tape Sheath Thickness Approx. O.D. Approx. Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
Weight In air (A) In soil(A)
1×25 7/2.17+0.01 3.4 0.12 0.2 1.8 23.9 854 0.727 24 165 160
1×35 7/2.56+0.01 3.4 0.12 0.2 1.8 24.9 980 0.524 24 205 190
1×50 19/1.86+0.01 3.4 0.12 0.2 1.8 26.2 1141 0.387 24 245 225
1×70 14/2.56+0.01 3.4 0.12 0.2 1.8 27.9 1392 0.268 24 305 275
1×95 19/2.56+0.02 3.4 0.12 0.2 1.9 29.7 1700 0.193 24 370 330
1×120 24/2.56+0.02 3.4 0.12 0.2 1.9 31.2 1974 0.153 24 430 375
1×150 30/2.56+0.01 3.4 0.12 0.2 2.0 32.8 2286 0.124 24 490 425
1×185 37/2.56+0.02 3.4 0.12 0.2 2.0 34.6 2700 0.0991 24 560 480
1×240 48/2.58+0.02 3.4 0.12 0.5 2.1 38.8 3685 0.0754 24 665 555
1×300 60/2.58+0.02 3.4 0.12 0.5 2.2 41.2 4350 0.0601 24 765 630
1×400 60/2.93+0.02 3.4 0.12 0.5 2.3 44.5 5342 0.047 24 890 725
1×500 60/3.33+0.02 3.4 0.12 0.5 2.4 47.9 6432 0.0366 24 1030 825
1×630 60/3.76+0.02 3.4 0.12 0.5 2.5 51.7 7896 0.0283 24 1200 950
3×25 7/2.17+0.01 3.4 0.10 0.5 2.4 46.1 2913 0.727 24 120 125
3×35 7/2.56+0.01 3.4 0.10 0.5 2.4 48.3 3329 0.524 24 140 155
3×50 19/1.86+0.01 3.4 0.10 0.5 2.6 52.3 3967 0.387 24 165 180
3×70 14/2.56+0.01 3.4 0.10 0.5 2.7 56.3 4840 0.268 24 210 220
3×95 19/2.56+0.02 3.4 0.10 0.5 2.8 60.0 5830 0.193 24 255 265
3×120 24/2.56+0.02 3.4 0.10 0.5 2.9 63.6 6783 0.153 24 290 300
3×150 30/2.56+0.01 3.4 0.10 0.5 3.0 66.8 7778 0.124 24 330 340
3×185 37/2.56+0.02 3.4 0.10 0.5 3.1 71.1 9183 0.0991 24 375 380
3×240 48/2.58+0.02 3.4 0.10 0.5 3.3 76.5 11217 0.0754 24 435 435
3×300 60/2.58+0.02 3.4 0.10 0.5 3.5 81.8 13337 0.0601 24 493 485
3×400 60/2.93+0.02 3.4 0.10 0.8 3.7 89.8 17258 0.047 24 565 520
 

 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

Packing and shipping

steel wooden drum, other as required and shipping in general is by sea.

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zhejiang CHINT Cable Co., Ltd
Location 1#Jiangnan Road,Nanhu district ,Jiaxing city, Zhejiang province China
Contact Person May

Request A Quote

Please check your email address.
Your message must be at least 20 characters.