Outdoor 36kV GCB SF6 Gas Circuit Breaker Substation Type With Long Service Life

Price Negotiable
Price: Negotiation
MOQ: Negotiation
Delivery Time: Depends on the quality of client
Brand: DINGLI
Product Description

Outdoor 36kV GCB SF6 Gas Circuit Breaker Substation Type With Long Service Life

 

Quick Detail: Indoor high voltage vacuum circuit breaker

DINGLI strives to bring our customers the latest technology and competitive pricing and best service for distribution

automatic GCB medium voltage circuit-breakers for outdoor installation use sulphur hexafluoride gas (SF6) to extinguish

the electric arc and as the insulating medium. Breaking in SF6 gas takes place without current chopping or generation

of overvoltages. These characteristics guarantee a long electrical life for the circuit-breaker and limited dynamic di-electric

and thermal stresses on the installation.
The GHS type of stored energy and free release mechanical operating mechanism allows opening and closing operations

through local and remote control. The operating mechanism, the activating kinematics of the moving contacts and the

anti-condensation heater are located inside a tight metal enclosure which also acts as the support for the poles. The

above-mentioned structure is supported by a frame made of telescopic metal sections which allow the height of the

circuit-breaker terminal to be adapted from 2800 mm to 3700 mm.
The metal enclosure has IP 54(*) degree of protection and is fitted with a tight door with an inspection window.The

circuit-breaker is compact and ensures a high level of sturdiness and excellent mechanical reliability.The enclosure

is made out of a steel plate with adequate surface protection by a special metalising and painting process. The support

structures are hot dip galvanised.

 

 

 

Main Contact Separation
No electric arc is struck because the current flows through the arcing contacts. During its run downwards,

the moving apparatus compresses the gas in the lower chamber. The compressed gas flows from the lower to

the upper chamber. hereby taking both the chambers to the same pressure.

Arcing Contact Separation
The current flows due to the electric arc which has struck between the arcing contacts. The gas cannot escape

through the nozzle because the hole is still closed by the fixed arcing contact and cannot even escape through

the inside of the arcing contact, because of the clogging effect of the electric arc.

No.
Item
Unit
Data
1
Model
 
GCB-12/24
GCB-36
GCB-40
2
Standards
 
IEC 62271-100
3
Rated voltage
kV
12/24
36
40.5
4
Rated Frequency
Hz
50-60
50-60
50-60
5
Rated Normal Current
A
1250
2500
1250
2500
1250
2500
6
Rated Breaking Capacity
kA
25/31.5
25/31.5
25/31.5
25/31.5
25/31.5
25/31.5
7
Rated Short Time Withstand Current(3s)
kA
25/31.5
25/31.5
25/31.5
25/31.5
25/31.5
25/31.5
8
Making Capacity
kA
63/80
63/80
63/80
63/80
63/80
63/80
9
Operation Sequence
 
O-0.3S-CO-15s-CO
10
Opening Time
ms
45+10
45+10
45+10
11
Arcing Time
ms
10-15
10-15
10-15
12
Total Breaking Time
ms
55-60
55-60
55-60
13
Closing Time
ms
75+10
75+10
75+10
14
SF6 Gas Absolute Pressure
kPa
380
380
550
15
Tropicalisation
 
IEC: 60068-2-30, 721-2-1
16
Electromagnetic Compatibility
 
IEC: 60694, 61000-6-2, 61000-6-4

 

Standards And Service

The GCB circuit-breakers comply with the IEC 62271- 100 standard as well as of other major industrialised countries.

They have undergone the tests indicated ensure service safety and reliability of the apparatus in alll installationsThe

mechanical and electrical locking devices have been provided to prevent incorrect operations and to carry out nspection

of the installations while guaranteeing maximum operator safety.

Workshop


Shipping: 

1. Specific packaging can be made to order.
You can specify other shipping methods such as Airmail, FEDEX or DHL. We shall let you know about the

shipping cost after receipt of your order.And also can send by sea or air, kindly send me the port of yours.
The standard procedure for making wooden case is as follows:


Technical Support
Technical support on pre-sales stage. DINGLI has own survey and engineering company with more than 100

engineers. We have special pre-sales engineer to work with customer at early stage of the project.
 

 

Site assistance
Site assistance in Latin American market, so far we have sales and service center in Spain, Chile, Bolivia, Peru,

Ecuador, Senegal, which will make a fast response for customer.

 

Customer Visit
Clients of Bolivia visited Dingli for factory inspection, we talked about the key issues faced right now, and found

ways to solve it together. They set a high value on this cooperation.

Customers and Partners of Dingli

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HENAN DINGLI POWER EQUIPMENT CO.,LTD.
Location ADDRESS:NO. 1394 EAST HANGHAI ROAD,ZHENGZHOU ECONOMIC AND TECHNOLOGICAL DEVELOPMENT ZONE,ZHENGZHOU CITY,HENAN PROVINCE,CHINA
Contact Person Julia

Request A Quote

Please check your email address.
Your message must be at least 20 characters.