Ultra Pure Water Reverse Osmosis EDI Membrane Stack Electro-Deionization (EDI/CEDI) Water Filtration Systems

 

E-Cell*-3X is designed to:

l Provide Ultrapure Water for industrial applications including Power, Semiconductor, and General Industry.

l Produce Mixed Bed quality water on a continuous basis.

l Require no caustic or acid for regeneration of ion exchange resin within the stack.

l Be leak free, guaranteed.

l Eliminate brine injection and concentrate recirculation, simplifying system design.

 

Description and Use

E-Cell-3X stacks are electrodeionization (EDI) stacks which use electrical current to deionize and polish reverse osmosis (RO) permeate water. The product water for the E-Cell-3X is at an Ultrapure level required in today’s demanding applications.

 

Typical Applications

l Microelectronics

l Power Generation (NOx, Boiler Feed)

l General Industry

 

Quality Assurance

l CE, UL & CSA marked

l Manufactured in a ISO 9001:2000 facility

 

E-Cell*-3X, 1 to 12 Stacks

Base System Features

l ECell3X Systems with 1 to 12 stacks for flow range of 15 – 336gpm (3.4 - 76.3 m3/h)

l Rectifier compatible with 400VAC & 50Hz or 460VAC & 60Hz

l Individual stack current monitoring

l Flow & pressure transmitters, ability to connect to SCADA system

 

System Options

l Allen Bradley Micrologix PLC with Ethernet

n Includes Veolia 6” Color QuickPanel View HMI

l NEMA 4 Terminal Box - removal of PLC & HMI and all wiring terminated at terminal box

l Standard Instrumentation

n Burkert Paddlewheel flow sensors on Dilute, Concentrate, and Electrode Outlet

n Burkert pressure transmitters on all streams

n Burkert conductivity analyzer and sensor on Dilute Outlet

l Premium Instrumentation

n Rosemount vortex flow transmitters on Dilute and Concentrate Outlet

n Burkert Paddlewheel flow sensor on Electrode Outlet

n Burkert pressure transmitters on all streams

n Rosemount conductivity analyzer and sensor on Dilute Outlet

l Inlet Divert Valve

n Standard Instrumentation: Burkert

n Premium Instrumentation: Rosemount

l ANSI to DIN conversion kits

 

Feed Water Requirements
Total Exchangeable Anions < 25.0 ppm
(as CaCO3) (TEA) Including CO2 as calculated by ECalc pH 4 – 11
Hardness < 1.0 ppm (as CaCO3)
Silica (Reactive) < 1.0 ppm
SDI (15 min) < 1
TOC < 0.5 ppm
Total Chlorine < 0.05 ppm
Fe, Mn, H2S <0.01 ppm

 

Operating Parameters
Outlet (Dilute) Product Quality > 16 MOhm-cm
Outlet Product Silica Guarantee Down to < 5ppb
Recovery Up to 95%
Temperature 40 to 104ºF (4.4 to 40ºC)
Feed Pressure 60 to 100 psi (4.1 to 6.9 bar)
Dilute Pressure Drop 20 to 40 psi (1.4 to 2.8 bar)
Input Voltage 460VAC 60Hz, 400VAC 50Hz

 

Material of Construction & Ratings
Welded Frame Painted Carbon Steel
Dilute Piping Sch. 80 PVC
Concentrate Piping Sch. 80 PVC
Flanges ANSI
Rectifier NEMA 4
Control Panel NEMA 4
Control Panel Power 24VDC

 

Ultra Pure Water Reverse Osmosis EDI Membrane Stack Electro-Deionization (EDI/CEDI) Water Filtration Systems

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuxi Fenigal Science & Technology Co., Ltd.
Location 606#, Building-B, 100 Dicui Road, Binhu District, Wuxi, Jiangsu, China
Contact Person Joe

Request A Quote

Please check your email address.
Your message must be at least 20 characters.