Elaborate Inverter Heating Air Conditioning Units LCD Remote Control Dehumidification
Cooling And Heating Stand Type Air Conditioner S18000BTU/24000BTU/36000BTU/48000BTU/60000BTU
Feature :
Function: Cooling only, Cooling and heating
High Efficiency Compressor
Hydrophilic Fins & Inner Threads Copper Tube
Quiet and Modern design
Remote Control
Sleep Operation
Strong Cooling And Heating
Wide Voltage Running
Latest Modern Design
Advantage
- Big LCD display
- Ultra-quiet design
- 24-hour timer
- LCD remote controller
- Fault self-diagnosis function
- Efficient energy saving
- Ultra-strong EMC
- Sleeping mode function
- Independent dehumidification (Dry mode)
Detailed specification:
|
Type |
18 |
42 |
48 |
60 |
|
Capacity |
|
|
|
|
|
Cooling Capacity Btu |
18000 |
42000 |
48000 |
60000 |
|
Heating Capacity Btu |
19800 |
48000+11000 |
52000+11000 |
60500+11000 |
|
Electricabl Parts |
|
|
|
|
|
Power Input (W) Cooling |
1810 |
4530 |
5100 |
6890 |
|
Heating |
1910 |
4940+3000 |
5200+3200 |
6660+3200 |
|
Operating Current (A) Cooling |
7.90 |
8.10 |
8.60 |
11.00 |
|
Heating |
7.90 |
8.6+4.5 |
8.6+5 |
11.0+4.5 |
|
Performance |
|
|
|
|
|
EER W/W |
2.92 |
2.65 |
2.76 |
2.55 |
|
COP W/W |
3.10 |
2.85 |
2.93 |
2.75 |
|
Air Flow Volume(m3/h) Indoor |
900 |
1800 |
2100 |
2200 |
|
Noise Level( dBA) Indoor/Outdoor |
29/55 |
45/62 |
45/63 |
46/63 |
|
Net Dimension & Weight |
|
|
|
|
|
Indoor(mm) |
500x1735x300 |
560x1910x360 |
560x1910x360 |
650x1897x370 |
|
Outdoor(mm) |
800x590x300 |
1255x945x340 |
1255x945x340 |
1255x945x430 |
|
Net Weight(kg) Indoor/Outdoor |
0.73 |
0.55 |
0.48 |
0.48 |
|
Packing Dimension& Gross Weight |
|
|
|
|
|
Indoor(mm) WxHxD |
620x1890x450 |
680x2020x510 |
680x2020x510 |
700x2010x400 |
|
Outdoor(mm) WxHxD |
940x650x420 |
1300x1085x430 |
1300x1085x430 |
1300x1085x430 |
|
Gross Weight(kg) Indoor/Outdoor |
41,54 |
61,117 |
64,135 |
70,143 |
|
Applicable Area |
|
|
|
|
|
Applicable Area m3 |
25~34 |
60~80 |
80~100 |
100~150 |
|
Loading Quantity |
|
|
|
|
|
Loading Quantity 20/40/40'HC |
40/78/90 |
18/38/48 |
18/38/48 |
18/38/46 |
Details
maintenance
1,Damages caused during the transportation,load,installation which made by upload, transportation ,installation principal.
2,During the debug,damages caused by inappropriate test behaviors should be on charge by the debug team.
3,After debugging is completed and the equipments can be work normally,any mistaken manual operations made by the users should be on charge for the damage.
4,Any movements,dissemble and repair /maintenance operated by other company or person which leads to damage should be on response.
5,Natural disasters result from force manure
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
