Power supply RC300 forced air cooling designed for taxi screen applications

Price Negotiable
Price: Negotiate
MOQ: 1
Delivery Time: 2-3 working days
Brand: SYSOLUTION
Product Description

 
Features
a. Cryogenic start.
b. High reliability : 100% full load aging test
c. Green LED light- Power supply indication status. d. Suitable for taxi-screen application.
e. Built-in DC fan forced air cooling.
 
Parameter

Power ModelRC300D4.2RC300D4.5RC300D5
ProjectFunctionParameter

 
 
 
 
 
 
 
 
 
 
 
 
 

Input

Characteri

stics

Input voltage range

 

9 ~36Vdc Typical values 12V 24V

Power

frequency
 

range

 
 
 

100~ 120KHz

Maxi input current

 

35A MAX

Full load efficiency

 

≥87%

 

≥88%

 

≥89%

Input

impulse
 

current

(cold boot)

 
 
 
 

Less than 100A, cold start

 

Output

Characteri

stic

Output voltage

 

4.2V

 

4.5V

 

5.0V

Output

voltage error

±3%±3%±3%
4.07V~4.33V4.35V~4.65V4.85V~5.15V
 range   

Output
 

current

 

0 ~60A

 

0 ~60A

 

0 ~60A

Maxi power250W270W300W
Ripple and noise200mVp-p MAX200mVp-p MAX200mVp-p MAX

Power

adjustment rage

 
 
 

±1%

Load

regulation

 

±2%

Output climb time

 

0.1~ 100mS/12Vdc @ full load

Output

holding time

 

≥10mS/12Vdc @ 80% of full load

 
 
 
 
 
 
 

Protective Properties

Out put
 

over-current protection

Output power 110%~160% protection.

Mode : burp mode, automatic recovery after removal of abnormal load conditions

Output short circuit

protection

Protected mode :burp mode, automatically restored after short circuit condition is

removed

OutputIf the output voltage exceeds the rated
 over-voltage protectionvoltage >2%, automaticallythe power supply will lock

Input back connect

protection

 

The input anode and cathode are connected to the reverse power supply

Over
 

temperature protection

 

The power supply exceeds the rated power and the overtemperature protection starts

Output Signal

Output

instruction

 

Led Power indication

 
 
Working Condition



 

Work parameter
Cooling modeNatural cooling
Working humidity requirement

 

20 ~90% non-condensing

Request of store temperature and humidity

 
 

-30 ~85℃,10~95%RH

Vibration

specification

 

10~500Hz,5G 10min./cycle,60min.each along X,Y,Z axis

 
Dimension


 

 
 

b. The power supply shall be installed directly in the metal box of the system for good heat dissipation. Under poor heat dissipation conditions, it is recommended to use a load of less than 80%.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Xixun Cloud Technology Company Limited
Location Room 719, Hai Liang Building B, ZhongJiang Road, 200062,PutuoDistrict, Shanghai ,China
Contact Person Emily Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.