Industry Maglev Centrifugal Blower Substitute For Roots Blower 138-180 M³/Min
138-180 m³/min Magnetic Bearing-levitation Centrifugal Blower - the great substitute for Roots Blower
Principle
The maglev centrifugal blower adopts high-speed motor, frequency converter and magnetic bearing integration structure. The output shaft of the motor is directly connected to the impeller, thus the mechanical speed increasing devices are no more required such as gears and couplings.
Variable frequency automatic regulation of air volume, air pressure and other output parameters. No mechanical contact, thus no oil lubrication system is required. The standard configuration includes high-speed motor, frequency converter, oil-free magnetic bearing, vent valve, local control, safety monitoring system and acoustic enclosure. All components are integrated and installed on the common base without special fixed foundation.
Key Components Description
- The magnetic bearing is the most important part of the whole machine, which is the active magnetic bearing. Based on the principle of constant magnetic attraction (similar to the German EMS technology adopted by Shanghai maglev train), the high speed and stable non friction suspension rotation of rotating shaft is achieved by electromagnetic attraction. By using position sensor, power amplifier and PI arithmetic device, real-time detection and corresponding adjustment of motor shaft, real-time fault diagnosis are carried out. Its active control ability can effectively prevent the shaft from vibration resulted from the unbalance and implement power-off protection.
- Impeller is made of solid aluminum alloy by CAM technology in CNC center. The impeller is of semi open design, and is directly connected to the motor shaft, while the blade is of three-dimensional shape, which can be optimally configured according to the actual design requirements of the machine.
- Volute and fan outlet are integrated.
- The cooling mode of inverter motor is air cooling. The motor shaft placed vertically is directly connected to impeller and motor cooling fan, and runs through magnetic bearing and frequency converter.
Product feature
By using frequency conversion to adjust output parameters and non-contact rotation, it can effectively save energy and reduce operation and maintenance costs.The equipment is small in volume, light in weight and easy to install and operate. Low noise and no vibration during operation.
Our Technical Advantages
Relying on Famous Professional University in China and the resource advantages of senior compressor enterprises in Mainland China, GoodSeaA has continuously increased its R&D investment and cultivated a talent team. On the other hand, it has accelerated the connection of universities,research institutes, large state-owned enterprise technical experts and the wisdom&brain resources of foreign related fields. It has also integrated the resources between related laboratories of universities and research institutes,high precision manufacturing capacity of military supporting enterprises and other related cooperation system,focusing on the segment market of “energy power optimization", form a strong synergistic and comprehensive capabilities in energy power field,including top-level technology research and development, products, manufacturing, installation and service.
- Turnkey engineering service
- System solution
- On-site guidance of installation, training, etc.
- Special maintenance service
- Guarantee time: 12 months for Whole equipment, 24 months for Core parts(impeller & volute)
- 24-hour response and on-site service after sale
Parameters of Magnetic bearing-levitation centrifugal blower
|
MODEL |
Power KW |
Pressure Kpa |
Air Flow m3/min |
Outlet Connection |
DIMENSION L*W*H mm |
WEIGHT KG |
|
GDE75-04 |
75 |
40 |
95 |
DN300 |
1780x860x1560 |
800 |
|
GDE75-06 |
60 |
66 |
DN200 |
|||
|
GDE75-08 |
80 |
53 |
||||
|
GDE75-09 |
90 |
45 |
||||
|
GDE100-04 |
100 |
40 |
120 |
DN300 |
1980x1050x1750 |
1050 |
|
GDE100-06 |
60 |
85 |
||||
|
GDE100-08 |
80 |
68 |
DN200 |
|||
|
GDE100-10 |
100 |
55 |
||||
|
GDE150-04 |
150 |
40 |
180 |
DN300 |
2080x1150x1850 |
1150 |
|
GDE150-05 |
50 |
150 |
||||
|
GDE150-06 |
60 |
138 |
||||
|
GDE150-07 |
70 |
118 |
||||
|
GDE150-08 |
80 |
109 |
DN250 |
|||
|
GDE150-09 |
90 |
90 |
||||
|
GDE200-04 |
200 |
40 |
236 |
DN400 |
2280x1300x2000 |
1450 |
|
GDE200-05 |
50 |
192 |
||||
|
GDE200-06 |
60 |
162 |
DN300 |
|||
|
GDE200-07 |
70 |
150 |
||||
|
GDE200-08 |
80 |
135 |
||||
|
GDE200-09 |
90 |
115 |
||||
|
GDE200-10 |
100 |
108 |
||||
|
GDE200-12 |
120 |
100 |
||||
|
GDE300-05 |
300 |
50 |
288 |
DN500 |
3080x1650x2100 |
2050 |
|
GDE300-06 |
60 |
270 |
||||
|
GDE300-08 |
80 |
215 |
DN400 |
|||
|
GDE300-10 |
100 |
172 |
||||
|
GDE300-12 |
120 |
130 |
DN300 |
|||
|
GDE300-15 |
150 |
110 |
||||
|
GDE400-05 |
400 |
50 |
392 |
DN600 |
3350x1850x2200 |
2360 |
|
GDE400-06 |
60 |
335 |
||||
|
GDE400-08 |
80 |
270 |
DN500 |
|||
|
GDE400-10 |
100 |
230 |
||||
|
GDE400-12 |
120 |
195 |
DN400 |
|||
|
GDE400-15 |
150 |
160 |
||||
|
Remarks 1.Above Design Parameters are obtained based on below conditions: We assume the inlet volume flow is defined as the standard of 20℃ suction temperature and 1atm
2.We reserve the right to update the referred contents. Some parameters can be changed according to the actual needs. Please refer to the pre-sale service.
|
||||||
Get in Touch