Indoor Lbs Load Break Switch 11kv 20 Kv / Hv High Voltage Isolators Easy Operation
Price:
Negotiation
MOQ:
1 Piece/Pieces
Delivery Time:
Negotiable
Brand:
XK
Product Description
Hot sale 12KV safety indoor AC high voltage load breaker switch
Product Description
| ltem | Unit | Data | |
| Rated voltage | KV | FN12-12D/630 | FN12-12(R)D/125 |
| Rated frequency | HZ | 12 | |
| Rated current | A | 50 | |
| 1min power frequency withstand voltage | KV | 42 to ground and phases fracture 48 | |
| Lightning impulse withstand voltage | KV | 75 to ground and phases fracture 85 | |
| Rated thermal stable current | KA |
630
|
100
|
| Rated dynamic stable current | KA |
50
|
|
| Rated switching current(peak) | KA |
50
|
50
|
| Rated short-circuit current(expected) | KV |
31.5
|
|
| Maximum breaking current threshold | HZ | Fuse characteratic curve accorting | |
| Minimum breaking current | A | Fuse characteratic curve accorting | |
| Rated transfer current | KV |
50
|
1.5
|
| Maximum breaking current | KV | 1.8 | |
| Breaking OFF-load transformer capacity | KV/A | 1250 | |
| Rated cable charging current | A | 10 | |
| Rated active load current breaking times | Times | 10000 | |
| Opening time when striker strikes | S | <0.06 | |
| Earth switch thermal current switch | KA | 20(2S) | |
| Thermal stable current of earth switch | KA | 50 | 50 |
| Motor operating power supply voltage | V | AC/DC 110/220 | |
11kv indoor load break switch 24kv load break switch high voltage isolators
| ltem | Unit | Data | |
| FN12-10D/630 | FN12-10(R)D/125 | ||
| The total traveling distance of moving contact | mm | 200+8-2 | |
| Phase center distance (Before energy storage) | mm | 210±15 | |
| Moving contact overtravel distance | mm | 40±2 | |
| Auxiliary contact opening distance | mm | >150 | |
| Opening/Closing time difference among three phase | ms | <3 | |
| Opening speed | m/s | >2.8 | >2.8 |
| Closing speed | m/s | >3.8 | |
| Distance between metal flexible door and torch | mm | >125 | |
| Fracture distance of earth switch | mm | >150 | |
| Main circuit resistance | Ω | <120 | <300 |
| Maximum operating torque | NM | >160 | |
11kv indoor load break switch 24kv load break switch high voltage isolators

We are recognized as a successful name of Load Break Switch in the market at present. Being compact in size these are used in smallest of the devices. These also traverse up / down or tilt outside or on one side of the sensor stem. These are made available to the customers at industry leading rates. These are provided as per the set industry norms and guidelines.
Features
Side mounting
Efficient sensor stems
Breaks off the loads
Applications
Power supplies
Electrical industry
Electricity components
Request
Callback
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
Location
No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
Contact Person
Meng