Battery Powered 10mm Accuracy 300kHz Ultrasonic Level Sensor

Price Negotiable
Price: Negotiable
MOQ: 1 Piece
Delivery Time: 3~30 working days
Brand: YUJIE
Product Description

High Accuracy Ultrasonic Sensor Level Measurement With Pipe Stainless steel Housing
 Highlights

TECH-IN
Temperature compensate
LED for status indication
Battery powered
Minmal dead bands
 
Applications
 
Liquid and Solid Level Measurement
Tanks,Totes,Processing
Bulk Material Management
Factory automation
Position Detection
Avoid collision

 
Ultrasonic sensor Ultrasonic sensor UM500-18GM-SP
 

Technical data  
General Specifications
Sensing distance 40…450mm(30---350mm)
Adjustment range 40…450mm(30---350)
Unusable area 0…40mm(0---30mm)
Standard target plate 100mm×100mm
Transducer frequency About 300 kHz
Response delay About 125ms
Indicators/Operating means

LED yellow solid: object in evaluation range
flashing: program function

LED red flashing: fault or program function object not detected
   
Electrical specifications
Operating voltage UB 10…30VDC,ripple10%ss
No-load supply current ≤20mA
Output
Output type 1 switch output E4,NPN NO/NC,programmable
Resolution 0.11mm at max.sensing range

 
 
 
 
 
 
 
 

Deviation of the characteristic
curve ±1% of full-scale value

Repeat accuracy ±0.1% of full-scale value

Load impedance >1k Ohm
Maximum switching current 200 mA (reverse polarity protection)

Temperature influence ±1.5% of full-scale value
Ambient conditions
Ambient temperature -25…70℃
Storage temperature -40…85℃
Mechanical specifications
Protection grade IP67
Connection Connector M12x1,4-PIN

 
1 BN=BROWN
2 WH=WHITE
3 BU=BLUE
4 BK=BLACK
V1 Connector

 

Material
Housing brass,nickel-plated

Transducer epoxy resin/hollow glass sphere mixture;

Polyurethane foam

Weight 60g
Compliance with standards and directives

Standard conformity EN 60947-5-2:2007

Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB,A2 with +UB. Five different output functions can be set.

  • Window mode, normally-open function.
  • Window mode, normally-closed function.
  • One switching point,normally-open function
  • One switching point,normally-closed function.
  • Detection of objet presence.

Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.

TEACH-IN window mode,normally-open function
-Set target to near switching point
-TEACH-IN switching point A1 with - UB
-Set target to far switching point
-TEACH-IN switching point A2 with + UB

 

TEACH-IN window mode,normally-closed function
-Set target to near switching point
-TEACH-IN switching point A2 with + UB
-Set target to far switching point
-TEACH-IN switching point A1 with - UB

 

TEACH-IN switching point, normally-open function
-Set target to near switching point
-TEACH-IN switching point A2 with + UB
-Cover sensor with hand or remove all objects from sensing range
-TEACH-IN switching point A1 with - UB

 
Curve1:flat surface 100mm×100mm
 Curve2:round bar,Φ25mm

TEACH-IN switching point, normally-closed function
-Set target to near switching point
-TEACH-IN switching point A1 with - UB
-Cover sensor with hand or remove all objects from sensing range
-TEACH-IN switching point A2 with + UB

TEACH-IN detection of objects presence
-Cover sensor with hand or remove all objects from sensing range
-TEACH-IN switching point A1 with - UB
-TEACH-IN switching point A2 with + UB

Default setting of switching point
A1=blind range,A2=nominal distance

LED displays  
Displays in dependence on operating mode Red LED Yellow LED  

TEACH-IN switching point
Object detected
No object detected
Object uncertain(TEACH-IN invalid)

 

off

flashes

On

 

flashes

off

off

 
Normal operation off Switching state  
Fault on Previous state  

Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Yujies Technology Co., Ltd.
Location Room 1807,Block A,Qunxing-Square,Huaqiang North Road,Shenzhen,Guangdong,China
Contact Person Dream Chan

Request A Quote

Please check your email address.