Fire Resistant PVC Sheathed Copper XLPE Power Cable

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 8-15 days
Brand: HOLD-ONE
Product Description

Fire-resistant XLPE sheathed power cable

 

XLPE sheathed power cable

 

This kind of cable has a special fireproof coating, so it has excellent heat insulation and fireproof performance. It is mainly used for fire protection, surveillance and alarm equipment in modern urban buildings and places with strict safety requirements, such as emergency lighting, control and power circuits, power stations, fire alarm systems, underground tunnels, elevators, escalators and high-rise buildings.
When burning, this kind of cable will not diffuse and burn, will not emit halogen and low smoke, is non-toxic, can protect people from suffocation and corrosion, and can help the instrument avoid damage. Compared with PVC cables, XLPE cables have a higher long-term working temperature and a larger rated current. Under the same conditions, the XLPE insulation layer is thinner than that of PE or PVC, which not only improves the quality and performance of the cable, but also Reduced our production costs.

 

Physical and Electrical Characteristics

 

No.cores x Insulation Sheath Outer Ø weight Current ratings in air 30℃ Current ratings buried 20℃
cross-sec. thickness thickness approx. approx.
  Nominal
Phase Neutral value
mm² mm mm mm mm kg / km A A
3×4+1×2.5 0.7 0.7 1.8 12.7 277 37 47
3×6+1×4 0.7 0.7 1.8 13.9 363 47 60
3×10+1×6 0.7 0.7 1.8 16.1 527 64 81
3×16+1×10 0.7 0.7 1.8 18.6 766 85 106
3×25+1×16 0.9 0.7 1.8 22.2 1140 113 137
3×35+1×16 0.9 0.7 1.8 24.6 1475 139

164

 


 Product characteristics


1.1 The long-term allowable working temperature of the cable conductor does not exceed 70°C;
1.2. When short-circuited (the longest duration does not exceed 5 seconds), the maximum temperature of the cable conductor does not exceed 160°C;
1.3. The ambient temperature when laying cables should not be lower than 0°C.
2. Use characteristics
2.1 The maximum rated temperature of the cable conductor is 90°C, and the short-circuit time (the longest duration does not exceed 5S), and the maximum temperature of the cable conductor does not exceed 250°C.
2.2 The ambient temperature when laying the cable should not be lower than 0°C
2.3 The bending radius should be allowed when laying: single-core cables are not less than 15 times the outer diameter of the cable; multi-core cables are not less than 10 times the outer diameter of the cable

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Qingdao Yilan Cable Co., Ltd.
Location East of Ping'an Avenue, Jiaoxi Town, Jiaozhou City, Shandong Province
Contact Person Alex

Request A Quote

Please check your email address.
Your message must be at least 20 characters.