VEIKONG Solar Pump Inverter 15HP 20HP 30HP 40HP 220V 380V with 99% MPPT Efficiency
Advanced solar pump inverter supporting both single-phase (220V) and three-phase (380V) configurations with power ratings from 0.75kW to 160kW. Engineered for reliable solar-powered water pumping applications with comprehensive protection features.
- Maximum MPPT efficiency exceeding 99%
- LCD display for real-time monitoring
- GPRS remote control capability (2G/3G/4G)
- Supports both IM and PM pump types
- Hybrid AC and DC operation
- Dry run protection system
- Full water and low water level protection
- One-button AC switching functionality
- Special solar MPPT and PID modes
- Macro mode for customized operation
| Parameter | 220V Model | 380V Model |
|---|---|---|
| Max Input DC Voltage | 450V | 810V |
| DC Voltage Range | 150-450VDC | 300-810VDC |
| Normal Working DC Voltage | 260-400V | 400-650V |
| Recommended MPPT Voltage | 330V | 550V |
| Rated Output Voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
| Output Frequency Range | 50/60Hz | |
| Max Efficiency | 99% | |
| Power Range | 0.75kW to 75kW | 1.5kW to 160kW |
| Cooling Method | Air Cooling | |
| Protection Degree | IP20/IP65 | |
| Altitude Rating | Below 1000m; above 1% for every additional 100m | |
| Certifications | CE/ROHS | |
| Drive Model | Voltage | Max DC Input (V) | Rated Output Current (A) | Applicable Water Pump (kW) | Size |
|---|---|---|---|---|---|
| VFD500M-20T00150-PV | 220V | 800 | 7 | 1.5 | A |
| VFD500M-20T00220-PV | 220V | 800 | 10.6 | 2.2 | A |
| VFD500M-40T00150-PV | 380V | 800 | 4.2 | 1.5 | A |
| VFD500M-40T00220-PV | 380V | 800 | 6 | 2.2 | A |
| VFD500-20T00150-PV | 220V | 800 | 7 | 1.5 | A |
| VFD500-20T00220-PV | 220V | 800 | 10.6 | 2.2 | A |
| VFD500-20T00400-PV | 220V | 800 | 17 | 4 | A |
| VFD500-40T00150-PV | 380V | 800 | 4.2 | 1.5 | A |
| VFD500-40T00220-PV | 380V | 800 | 6 | 2.2 | A |
| VFD500-40T00400-PV | 380V | 800 | 9.4 | 4 | A |
| VFD500-40T00550-PV | 380V | 800 | 13 | 5.5 | B |
| VFD500-40T00750-PV | 380V | 800 | 17 | 7.5 | B |
| VFD500-40T01100-PV | 380V | 800 | 25 | 11 | C |
| VFD500-40T01500-PV | 380V | 800 | 32 | 15 | C |
| VFD500-40T01850-PV | 380V | 800 | 38 | 18.5 | D |
| VFD500-40T02200-PV | 380V | 800 | 46 | 22 | D |
| VFD500-40T03000-PV | 380V | 800 | 60 | 30 | E |
| VFD500-40T03700-PV | 380V | 800 | 75 | 37 | E |
| VFD500-40T04500-PV | 380V | 800 | 96 | 45 | F |
| VFD500-40T05500-PV | 380V | 800 | 112 | 55 | F |
| VFD500-40T07500-PV | 380V | 800 | 150 | 75 | G |
| VFD500-40T09000-PV | 380V | 800 | 176 | 90 | G |
| VFD500-40T11000-PV | 380V | 800 | 210 | 110 | H |
| VFD500-40T13200-PV | 380V | 800 | 253 | 132 | I |
| VFD500-40T16000-PV | 380V | 800 | 304 | 160 | I |
| VFD500-40T18500-PV | 380V | 800 | 340 | 185 | J |
| VFD500-40T20000-PV | 380V | 800 | 377 | 200 | J |
- GPRS Module (supports 2G/3G/4G internet connectivity)
- LCD Keypad for local control and monitoring
- Output Reactor for enhanced performance
For keyboard control: No parameter settings required. For external switch control: Set P00.06=1 and connect COM and DI1 with a wire or switch. When the switch closes, the drive runs; when open, the drive stops.
For digital float signals: Use float switch to short DI3 and COM (refer to diagram 1.3).
Set P47.05=30Hz, P47.06 to desired time, and P47.07 to desired time. Refer to detailed documentation for P47.05-47.07 parameters.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.