Technical Specifications
Parameter 220V Model 380V Model
Max Input DC Voltage 450V 810V
DC Voltage Range 150-450VDC 300-810VDC
Normal Working DC Voltage 260-400V 400-650V
Recommended MPPT Voltage 330V 550V
Rated Output Voltage 1/3-phase 220VAC 3-phase 380-480VAC
Output Frequency Range 50/60Hz
MPPT Efficiency >99%
Max System Efficiency 99%
Power Range 0.75kW to 75kW 1.5kW to 160kW
Cooling Method Air Cooling
Protection Degree IP20/IP65
Operating Altitude Below 1000m; above 1% for every additional 100m
Certifications CE/ROHS
System Design Recommendations

Solar panel power should be 1.3-1.4 times higher than solar pump power, and solar pump inverter power should be higher level than solar pump. For distances over 100m between pump and inverter, use output reactor or higher power inverter. Solar panel total VOC must be less than inverter maximum DC voltage.

Key Features & Advantages
  • Built-in EMC C3 filter with advanced software and unique design
  • Compatible with single phase, three phase, and permanent magnet synchronous pumps
  • Dual input support: PV and AC input simultaneously for 24-hour operation
  • High-efficiency MPPT technology with up to 99.9% efficiency
  • Water level detection with automatic flow regulation and dry-running protection
  • Water full protection function for system safety
  • Optional LCD keypad and GPRS module for easy operation and monitoring
  • Built-in soft start, overvoltage, overload, undervoltage and weak sunshine protection
Product Applications
MPPT solar pump inverter application diagram showing system configuration
MPPT solar pump inverter unit showing front panel and connections
MPPT solar pump inverter technical specifications and wiring diagram
Frequently Asked Questions
How to achieve automatic start after stop?

For keyboard control: no parameter setting needed. For external switch control: set P00.06=1 and connect wire/switch between COM and DI1.

How to design solar PV water pump system?

Key requirement: PV array VOC and VMP must match inverter input range. Technical support available online.

How to use float switch for water tank full protection?

For digital float signals: use float switch to short DI3 and COM terminals.

How to set minimum and maximum frequency?

Set P47.05=30Hz for minimum frequency, with timing parameters in P47.06 and P47.07.

How to make system work without sunshine?

Connect power grid or diesel generator to inverter AC input for continuous operation during low sunlight conditions.

How to troubleshoot inverter trips and errors?

Check solar panel VMP/VOC, motor power/current, distance between motor and inverter, trip records (R25.00-R26.03), and motor insulation/blockage.