LK-YAN8300A /LK-YAN8600A/LK-YAN7200A Anesthesia Machine

Price Negotiable
Price: $8,749.00 - $20,000.00
MOQ: 1 Set/Sets (Min. Order)
Delivery Time: Within 7 days after getting payment
Brand: HangKang
Product Description
1.PCV and SIMV+PS modes ensure flexibility in ventilation, suitable for both pediatric and adult operation
2. Flowmeter with backlight, suitable for endoscopy surgery etc.
3.Breathing system warmer for avoid condensation build-up during low-flow anesthesia
4. Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
5. Optional functions monitoring O 2 , CO 2 and anesthetic gas
6.With CE certificate, meets EU clinical requirement
Dimensions(W×H×D)
704mm × 1403mm × 750mm
Weight
115kg (including trolley base and 2 vaporizers without cylinder
Operation Temperature
+10~+40°C
Operation Humidity
≤80% (noncondensing)
Battery
24V DC, minimum 120 min
Patient Types
Adult, Pediatric

 

 
Technical Specifications:
 

Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa

safety valve <12.5 kPa

Respiratory Rate 1~99 bpm

gas concentration output 21% ~ 100% adjustable

Maximum Minute ventilation ≥18L / min, permissible deviation: ±20 %

Breathing Mode A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV, PEEP,SIGN,VCV, SPONT, MANUAL

Ventilator compliance ≤30 Ml/kPa

PEEP: 0~1.0KPa

Ptr: ,-1.0~1.0 kPa

IMV frequency: 1 ~ 12 times/min, permissible deviation: ±15%.

I/E Ratio: 4:1~1:4

Tidal Volume range 0~2000ml

Inspiratory Plateau: 0~1s

Maximum Safety Pressure ≤ 6.0kPa

Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point and the permissible error is -10% or 15%.

Pressure limit range: 1.0~ 6.0kPa

Airway pressure alarm: Audible and visual and with yellow and red color indicating upper alarm: 0.9 kPa ~ 5.4 kPa

lower: 0.5kPa

Ventilation Volume alarm: ≥ 18L/ MIN

Power Supply Alarm "Ac/dc power supply are after failing to send out alarm immediately

Alarm Time: keep >120s"

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.

 
Ambient temperature 10 ~ 40oC
Relative humidity no higher than 80 %
Atmospheric pressure 860 hPa ~ 1060 hPa
Power requirement 100-120 Vac, 50/60 Hz;
Air source requirement Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention the AC power supply used for the anesthesia machine must be well grounded.
Attention the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment
Part II Special Requirements for Safety and Basic Performance of Anesthesia System.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShanDong HangKang Medical Equipment Co.,Ltd.
Location A703-03, Jinquan Dasha, 56 Jiefang DongLu, Lixia district , Jinan City , Shandong province 
Contact Person Aana Yue

Request A Quote

Please check your email address.
Your message must be at least 20 characters.