Product Description

Centrifugal Blower Fan (GY6-41) for Industrial Using

Introduction Of 6-41 blower fan

 

Centrifugal Blower Fan, high-temperature boiler induced draft fan The usage of the ventilator The model G, Y6-41 boiler centrifugal drum and the induced draft fan is designed for adapting the industrial boiler that burns a variety of coal and is equipped with dust and smoke removal devices. The new series of low noise...

Centrifugal Blower Fan:

High-temperature boiler-induced draft fan


The usage of the ventilator

The model G, Y6-41 Centrifugal boiler Blower Fan, and induced draft fan are designed for adapting the industrial boiler that burns a variety of coal and is equipped with dust and smoke removal devices. The new series of low-noise boiler drums and induced draft fans with the highest total pressure efficiency of higher than 80% can be selected by all the items with the equivalent intake conditions and suitable performance.
The features of the ventilator

The model G, Y6-41 series centrifugal ventilator is a replacement product of the boiler drum and induced draft fan.

The design method of the model G, Y6-41 series ventilator follows the design principles of selecting the appropriate ventilator type, reasonable operating parameters and preferred flow pattern, organizing the gas source reasonably, designing the blade type carefully, increasing the gap of wind tongue, reducing the rotate speed appropriately, improving the volute design, purifying flow and minimizing the secondary flow loss as much as possible, etc. Moreover, the conduct optimal design for the wind gap by the combination of using the finite difference method for the numerical calculation of the air inlet and impeller cap lines and taking the flow field uniformity at the fan impeller inlet as the optimization criterion. Then, combine the above method with the original, optimized design method of fan impeller and volute to integrate the optimal design procedure of impeller, volute, and air inlet with a lower noise level and smaller size of the fan.

 

Centrifugal Blower Fan, model G, and Y6-41 series ventilators have been tested by Shenyang Blower Research Institute and have achieved good results. The test data is quoted as follows:

Induced draft fan: Y6-41-11No7.1C matched with 4 tons / hourly coal-fired boiler:

Working temperature: 20 The features of the ventilator

0 ° C; rotate speed: 2100 rev/min
Design operating parameters: flux: 12500 m³ / h; full pressure: 2596 Pa

 

Technical data

 

Model No GY6-41 3.55C-8.5A
Use Smoke and dust removal
Voltage 380V/400V/415V/440V/450V/660V/1140V
Color Blue/Red/White/Grey/Yellow/Customized
Application Industries Steel Mill/Textile, Chemical, Smelting, Petroleum, and Kiln, and Many Factories
Specification Can provide according to customers' requirements
Brand Name SIMO
Power O.55~55KW
Rotating Speed  2800~1480rpm
Total Pressure 51~4086Pa
Airflow 1043~21M3/h
Package Wooden Box/Steel frame
Temperature Resistance -40~350 Degrees
Material SS304,SS316 and Q235
Frequency 50Hz/60Hz
Impeller Type Backward/Forward/Radial Blade
After-Sales Service Field Installation, Commissioning, and Training
Efficiency(%) Over 90%
Exported to All Countries
Warranty 18 Months

 

FAQ

1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.

 

 

company introduction

 

Xinxiang SIMO Blower Co., Ltd., formerly known as Xinxiang Blower Factory, was established in 1955, which is the designated factory for fan production by the former Ministry of Machinery Industry. In 2006, the state-owned enterprise was restructed. In August 2008, the company was registered as Xinxiang SIMO Blower Limited Company, with a registered capital of RMB32,000,000. In June 2016, the company was renamed as Xinxiang SIMO Blower Co., Ltd. In May 2018, the national SME share transfer system was listed. It is one of the larger fan manufacturers in central China and a member unit of China Fan Association. SIMO Blower is a state-level high-tech enterprise, safety production standardization of level3 enterprise, a provincial level1 advanced management enterprise, and has won more than 20 provincial and municipal honorary titles such as "contract-honoring & trustworthy enterprise", "advanced quality management unit", and "customer satisfied enterprises". The company has passed the national level industrialization and information integration management system assessment, ISO9001 quality management system certification, ISO14001 environmental management system certification, OHSAS45001 occupational health and safety management system certification and CE certification.

 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xinxiang SIMO Blower Co., Ltd.
Location No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China
Contact Person Kevin Sun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.