ASME SA213 TP310S Stainless Steel Seamless Boiler Tube 25.4mm OD x 2.11mm Wall Thickness
Price:
800 - 9000 USD / ton
MOQ:
5T
Delivery Time:
60-75days
Brand:
HDT
Product Description
Product Overview
ASME SA213 TP310S stainless steel seamless pipe designed for boiler and heat exchanger applications. This high-performance tube measures 25.4mm outside diameter with 2.11mm wall thickness, manufactured to ASTM A213/A213M standards for superior performance in demanding thermal environments.
Material Specifications
Available Grades
| American Standard | European Standard | Russia Standard |
|---|---|---|
|
Austenitic Steel: TP304, TP304L, TP304H, TP304N, TP310S, TP316, TP316L, TP316Ti, TP316H Others: TP405, TP409, TP410, TP430, TP439 |
1.4301, 1.4307, 1.4948, 1.4541, 1.4878, 1.4550, 1.4401, 1.4404, 1.4571, 1.4438, 1.4841, 1.4845, 1.4539, 1.4162, 1.4462, 1.4362, 1.4410, 1.4501 | 08Х17Т, 08Х13, 12Х13, 12Х17, 15Х25Т, 04Х18Н10, 08Х20Н14С2, 08Х18Н12Б, 10Х17Н13М2Т, 10Х23Н18, 08Х18Н10, 08Х18Н10Т, 08Х18Н12Т, 08Х17Н15М3Т, 12Х18Н10Т, 12Х18Н12Т, 12Х18Н9, 17Х18Н9, 08Х22Н6Т, 06ХН28МДТ |
Size Range
| Production | Outside Diameter | Wall Thickness |
|---|---|---|
| Boiler Pipe | 6.00mm - 850mm | 0.5mm - 68mm |
Manufacturing & Finishing
Final Finishing: Solution Annealed & Pickled / Bright Annealed
Pipe Types: U-bend or Straight configurations available
Quality Assurance & Testing
Standard Quality Tests
| Test Type | Description |
|---|---|
| Corrosion Test | Conducted only when specially requested by the client |
| Chemical Analysis | Test done as per required quality standards |
| Destructive / Mechanical Testing | Tensile | Hardness | Flattening | Flare | Flange |
| Reverse-bend and Re. flat tests | Carried out in full compliance with relevant standards & ASTM A-450 and A-530 norms, ensuring trouble-free expansion, welding & use |
| Eddy Current Testing | Done to detect homogeneities in subsurface by using Digital Flaw-mark Testing System |
| Hydrostatic Testing | 100% Hydrostatic Testing carried out according to ASTM-A 450 norms for checking tube leakage, maximum pressure support 20Mpa/7s |
| Air Under Pressure Test | To check any evidence of air leakage |
| Visual Inspection | After passivation, every single length of tubes & pipes is subjected to thorough visual inspection by trained staff for detecting surface flaws & imperfections |
Supplementary Testing
- Eddy Current Testing
- O.P Testing
- Radiography Testing
- Corrosion Testing
- Micro Testing
- Macro Testing
- IGC Testing
- Ultrasonic testing
- Liquid Penetrate testing
Product Images
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
ZHANGJIAGANG HUA DONG ENERGY TECHNOLOGY CO.,LTD
Location
Rm. 1202, Buildiing A, Wanda Plaza, Zhangjiagang, Jiangsu, China
Contact Person
Yolanda Zou