Constant Temperature and Humidity Precision air conditionning 7.5KW three-phase 380V 50Hz
|
The Cool-smart series computer room precision air conditioner is an excellent solution for small and medium computer rooms, base stations, computer rooms, and other similar applications. Cool-smart offers big air volume and low enthalpy, as well as the benefits of high dependability, high efficiency, extended service life, and energy savings.
Benefits
![]()
|
![]() |
- Adopting a new generation intelligent PLC microcomputer controller, large LCD screen, with background light, modular menu, English display
- Record data such as various status, alarms of the unit, and historical data sharing
- Power-off data protection and power recovery automatic start-up design
- The powerful group control system of 32 sets units, energy efficiency management, timing rotation, fault braking switching, automatic implementation of group adaptive energy saving
- Standard RS485 communication interface, optional Internet interface, support Modbus/TCP, and other customized protocols.
- Optional GPRS module, automatic transmission of the unit running SMS, and prompt the specific state of fault, to facilitate maintenance timely and effectively.
- Large air volume and small enthalpy design, low energy consumption
- High—efficiency scroll compressor with high energy efficiency, high cooling capacity, low noise, and long working life
- Large-area multi-layer evaporator, designed with high-efficiency internal thread copper tube and self-cleaning heat exchange fin, which ensures the highest heat exchange efficiency to guarantee large cooling capacity.
- Large outdoor condenser cooling circuit design and outdoor speed control fan and condensing pressure automatic adjustment device
- Unique cooling and dehumidification automatic mode and thermal recovery technology (optional), reduce reheat compensation, highly efficient dehumidification, and energy saving.
|
![]() |
- IT equipment room
- Small data center
- Industrial clean room
- Constant temperature and humidity process workshop
- Laboratory
- Electric power equipment room
- Railway subway machine room
- Base station and small telecom switch room
- Medium & Small telecom switch room
|
![]() |
| Model |
M04 |
M06 |
M08 |
M13 |
M17 |
M20 |
| Power Supply |
220V1Ph-50Hz |
380V3Ph-50Hz |
| Air discharge |
Up Front/Down |
| Technical Data Sheet |
| AC Fan |
Total cooling capacity-KW |
4.2 |
6.4 |
7.5 |
12.5 |
17.5 |
20.2 |
| Sensible cooling capacity-KW |
3.9 |
5.8 |
6.9 |
11.3 |
15.7 |
18.3 |
| Unit FLA-A(heating, humidifying type) |
20.0 |
25.0 |
16.8 |
22.0 |
23.5 |
28.6 |
| Compressor Quantity |
1 |
| Fan Quantity |
1 |
| Air Volume-m3/h |
1600 |
1900 |
2300 |
3600 |
5100 |
6500 |
| Heater Capacity-KW |
3.0 |
3.0 |
6.0 |
6.0 |
6.0 |
6.0 |
| Humidification-kg/h |
3 |
3 |
3 |
3 |
6 |
6 |
| Power of humidifier-KW |
2.3 |
2.3 |
2.3 |
2.3 |
4.5 |
4.5 |
| Outdoor Condenser |
| Model |
SCA020 |
SCA020 |
SCA030 |
SCA030 |
SCA050 |
SCA050 |
| Standard unit operating temperature range-℃ |
-15-45℃ |
| Low-Temperature Components Operating Temperature Range-℃ |
-40-45℃ |
|
![]()
![]()