Flexible Capacity Management Containerized Data Center with 1100kg Static Payload and Custom Logo Label

Price Negotiable
Price: 8000-30000USD per set
MOQ: 1set
Delivery Time: 20-40 days
Brand: COOLNET
Product Description

Customized Containerized Data Center Flexible Capacity Management

 

 

Product Introduction                                                         

 The container data center shifts the design and most of the construction of the data center to the factory for pre-customization and builds it on site in the way of building blocks, thus achieving rapid deployment and significantly improving the efficiency of the data center. It will be servers, storage, network equipment, etc. a brain into the container, which is the container data center.

Coolnet container data center integrates AC/DC power supply, HVAC, closed cold/hot aisle, modular structure, fire fighting and intelligent monitoring. The single-container solution or multi-container solution can be used according to actual needs.The container data center solution is widely used in Internet, telecom, government, finance and other fields.

 

 

Advantages                                                                           

Low PUE
Data centers with obsolete equipment components tend to have low PUE values, which can lead to increased energy costs and carbon emissions. The use of container data centers can help solve these problems.


Higher space utilization
Traditional data centers require the construction or renovation of a completely turned around or new space. Whereas container data centers are more flexible and can be prevented from being located almost anywhere. This is particularly suitable for companies with unused office space or warehouses to adopt this type of data center. By using these spaces, you can avoid building new sites and delaying project implementation for this reason.

Globalization Standards
When trying to establish standard processes and operational specifications across national borders, companies often face many obstacles such as culture, language and equipment design. Container data centers offer simple solutions with standardized strategies for standardizing prefabricated equipment to help reduce engineering costs, training requirements, spare parts, field installation costs and field testing and custom programming.

 

Applications                                                                           

  • Cloud
  • Telecom
  • Edge computing
  • Content delivery network

 

Technical Parameter                                                                  

 

PRODUCT PARAMETERS ICDC20 ICDC40
Container Size 20'HQ 40'HQ
Rack Specification 600*1000*2000 600*1000*2000
Single Rack Capacity 42U 42U
Rack Quantity 4pcs 4pcs
Single Rack Max. Capacity 6KW 6KW
IT Equipment Total Capacity 24KW 48KW
UPS 25KVA*2
N+1 Modular UPS
25KVA*3
N+1 Modular UPS
Battery Back-up Time 10Minutes 10Minutes
Cooling Pattern Inrow Air Condition Inrow Air Condition
Monitoring system YES YES
Door Security System YES YES
Fire alarm and gas fire extinguishing system YES YES
Video Monitoring System YES YES
EPO YES YES
Transportability Support Support
Stackable Support Support
Application Outdoor Type Outdoor Type
Diesel Generator Module Extra position Extra position

 

Certification                                                                         

 

Factory View                                                            

 

Case                                                                          

 

 

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Coolnet power Co., ltd
Location High-tech Zone Mechanical and Electrical Industrial Park,Hefei City Anhui Province
Contact Person Janet Si

Request A Quote

Please check your email address.
Your message must be at least 20 characters.