Modular Design Micro Data Center with Low Latency and Environmental Monitoring for Smart IT Infrastructure
| Attribute | Value |
|---|---|
| Product Type | All-in-one data center |
| Refrigerant | R134a/R407C/R22/R410A |
| Application area | Network closets or telecom sites, Edge Computing |
| Voltage | 380v/220v,110-220v/50-60Hz,220V/50Hz |
| Operating power | 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
| Cabinet type | 26U 42U |
| Power | 3-30kv |
| Enclosed cabinet | Glass door |
A Micro Data Center (MDC) is a miniaturized, modular computing and storage facility that is typically used to handle computing needs in distributed environments. Compared with traditional large data centers, micro data centers have a smaller size, lower energy consumption, and higher flexibility, and are suitable for edge computing, remote office, retail stores, smart cities, and other scenarios.
Its modular design and standardized components enable faster deployment, and it can be flexibly expanded as needed to adapt to changing business needs. Despite its small size, micro data centers still have high reliability and availability, and are usually equipped with redundant power supplies, network connections, and backup devices to ensure stable system operation.
- Low latency: By bringing the "client" and "server" computers geographically closer, MDCs can lower latency significantly.
- Increased resilience: With MDCs, having dozens of failover options becomes feasible, reducing single points of failure.
- Faster deployment times: Micro data centers can be shipped partially or fully assembled, with significantly faster provisioning than traditional data centers.
- Standardization: Enables standardized and repeatable design, reducing opex and maintenance costs.
- Scalability: Allows businesses to incrementally scale up based upon demand for a more elastic and agile infrastructure.
- The box has the characteristics of dust-proof, sun-proof, rain-proof, etc., and is fully adaptable to the outdoor environment.
- The equipment warehouse cabinet adopts ventilation and heat dissipation.
- Each cabinet is equipped with DC lighting fixtures.
- The cabinet has sensing ability and environmental monitoring function, which can realize and upload alarms such as power failure, power failure, access control, temperature, humidity, smoke, water immersion, and battery voltage.
- The layout of the cabinet is reasonable, the cable introduction, fixing and grounding are convenient for operation and maintenance.
- Power cables, signal cables and fiber optic cables have separate entry holes and will not interfere with each other.
- The cables used in the cabinet are made of flame-retardant materials.
| Series | Conventional Air Conditioning Version | ||||
|---|---|---|---|---|---|
| System | EC20 | ER02 | ERO3 | ER05 | |
| Power supply and distribution | UPS Capacity | 3KVA | 6KVA | 10KVA | 20KVA |
| Power factor | 0.8 | 0.8 | 0.8 | 0.9 | |
| Total power input | 220V/40A | 220V/63A | 220V/125A | 380V/125A | |
| Height | 4U | 4U | 4U | 6U | |
| Lightning protection | Cclass | ||||
| Others | ATSModle(optional) | ||||
| Cabinet | Recommended number of IT cabinets | 1 | 2 | 3 | 5 |
| Available space | 28U | 33U+42U | 29U+2*42U | 30U+4*42U | |
| Number of PDUs in a single rack | 1*8bit10A | 1*12bit10A | 1*(12bit10A+4bit16A) | ||
| Closed aisle | Fully enclosed cold and hot aisle | ||||
| Ergency ventilation | Fan-type emergency ventilation system,support maximum 5KW heat dissipation,automatic start and stop | ||||
| IT space expansion | Standard IT cabinet with 42U usable space(optional) | ||||
| Refrigiration | Type | Rack mount | In row | In row | In row |
| Cooling Capacity(KW) | 3.5 | 7.5 | 12.5 | 2*12.5 | |
| Sensible heat ratio | 1 | ||||
| System | Compression system+EC fan | ||||
| Monitoring | Monitoring volume | UPS,Power distribution,AC,Water leakage,Temperature &Humidity.Smoke,Door sensor | |||
| Function | Data collection and storage,alarm management,energy consumption analysis, remote access,sound andlight alarm (optional),SMS alarm (optional),APP(optional) | ||||
| Display | 10-inch Touch screen | ||||
| Fire | Heptafluoropropane | 1URack-mounted gas fire extinguishing system (optional) | ||||
| Battery | Standard number of batteries | 8 | 16 | 16 | 20 | ||||
| Backup power for 15 minutes | 2UBattery Pack | 3UBattery Pack | 6UBattery Pack | ||
| Backup power for 40 minutes | External 20100A/12V | ||||
| Backup power for90 minutes | Can be replaced with high-capacity batteries or increase the number of battery packs (not more than 4) | ||||
| Size (W*D*H-mm) | 600*1200*2000 | 1500*1200*2000 | 2100*1200*2000 | 3600*1200*2000 | |
| Environment | Environment temperature | 0~45℃ | |||
| Environment humidity | Relative humidity 0-95%,no condensation | ||||
| Altitude | <1000m,The excess part is derated according to relevant standards | ||||