26.7kW In-Row Cooling Unit for Data Centers | High-Airflow EC Fan Design

Price Negotiable
Price: 3000-20000USD/Unit
MOQ: 1set
Delivery Time: 25-30 working days
Brand: COOLNET
Product Description
26.7kW In-Row Cooling Unit for Data Centers | High-Airflow EC Fan Design
Product Overview
Constant Temperature & Humidity Air Conditioner In Row Precision Air Conditioning For IDC
In-row air conditioners, also known as cool row air conditioning, are placed between server cabinet columns to provide direct cooling to heat sources. As part of mechanical room air conditioning systems, these units address the increasing heat dissipation from servers and communication equipment in data centers. Traditional forward air conditioning methods often fail to meet modern equipment temperature and humidity requirements. In-row cooling ensures cool air enters equipment directly for effective heat removal and prevents local overheating.
Features & Benefits
In-row cooling unit interior view showing components
In-row cooling unit installation in data center
Structure & Components
Detailed structure diagram of in-row cooling unit
Efficient EC Fan System
  • Saving 20%-30% energy compared to traditional AC motor
  • Motor soft-startup function with low startup current
  • Automatic rotary speed adjustment based on cooling requirements and airflow pressure
  • N+1 redundancy configuration of fans ensures continuous airflow during fan faults
  • Easy-maintenance design
High Efficiency Compressor System
  • Uses R410A refrigerant
  • Scroll compressor with high reliability and energy efficiency ratio
Electronic Expansion Valve
  • Smooth throttle adjustment for energy savings
  • Wide operational range reduces superheat degree and improves EER
  • Precise cooling capacity and heat load matching
  • Quick response for precise cooling control
EVO Control System
  • Graphic display showing running status and inlet/outlet air temperature/humidity
  • Advanced team work function supporting up to 32 units with easy network setup
  • Standard RS485 port with optional SNMP, TCP/IP interfaces, and GPRS with SMS
  • Standard communication protocol with optional customized specifications
High Flexibility
  • Air-cooled or chilled water-cooled cooling schemes available
  • Scalable design reduces initial investment - additional units can be easily added as cooling demand increases
  • High reliability and serviceability
  • 24*7 uninterruptible operation design
  • 4 levels of password protection
  • Service access via front or rear of the unit
Advantages
Key advantages of in-row cooling system
Technical Parameters
Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3
Certificates
Product certifications and quality standards
Factory Details
Manufacturing facility and production capabilities
Packing and Delivery
Product packaging and shipping process
Case Studies
Real-world installation case study

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Coolnet power Co., ltd
Location High-tech Zone Mechanical and Electrical Industrial Park,Hefei City Anhui Province
Contact Person Janet Si

Request A Quote

Please check your email address.
Your message must be at least 20 characters.