Coolnet CNER 1-10kVA Single Phase Rack Mount Online UPS with Pure Sine Wave Output, LCD Monitoring and Configurable Battery Backup for Server Rooms

Price Negotiable
Price: Contact us for a model-specific quotation
MOQ: 5units
Delivery Time: To be confirmed by configuration
Brand: COOLNET
Product Description
Coolnet CNER Single-Phase Rack UPS for Server and Network Cabinets

The CNER 1–10kVA range provides online double-conversion power protection for server rooms, network cabinets and telecommunications equipment. Select a model by both its kVA and kW rating, then match the battery configuration to the required backup time.

Key Features
  • Pure sine wave output and online double-conversion technology.
  • Zero mains-to-battery transfer time to support continuous operation during utility interruptions.
  • LCD/LED indication for load, battery capacity, operating modes and faults.
  • RS-232/USB communications, with an optional SNMP card for network monitoring.
  • Rack-format enclosures: 88mm-high 1–3kVA models and 133mm-high 6–10kVA long-backup models.
  • Standard and long-backup configurations available as specified below; runtime depends on load and battery selection.
Model Selection
Model Rated Capacity Long-Backup Dimensions (W * D * H) Long-Backup Net Weight
CNER-1101 / CNER-1101L 1kVA / 0.8kW 438 * 310 * 88mm 5kg
CNER-1102 / CNER-1102L 2kVA / 1.6kW 438 * 410 * 88mm 7kg
CNER-1103 / CNER-1103L 3kVA / 2.4kW 438 * 530 * 88mm 8kg
CNER-1106L 6kVA / 4.8kW 438 * 580 * 133mm 12kg
CNER-1110L 10kVA / 8kW 438 * 580 * 133mm 16kg

Dimensions and weights in this table apply to the L long-backup variants. Standard 1–3kVA units have different battery arrangements and weights. Product images show representative CNER series configurations; enclosure and battery arrangement vary by selected model.

Electrical and Operating Specifications
Input/Output Phase Single phase
Rated Input and Output Voltage 200/208/220/230/240VAC
Input Voltage Range 110–300VAC
Input Frequency Range 40–70Hz
Output Voltage Regulation ±1%
Output Frequency in Battery Mode 50Hz ±0.1Hz or 60Hz ±0.1Hz
Mains/Battery Transfer 0ms
Inverter/Bypass Transfer 1–3kVA: up to 4ms; 6–10kVA: 0ms, under catalog conditions
Mains and Battery Efficiency 1–3kVA: at least 91%; 6–10kVA: at least 93%
Operating Temperature 0–40°C
Relative Humidity 0–95%, non-condensing
Application and Configuration Guidance

For a server or communications cabinet, confirm the connected load in watts and VA, available rack depth, power connections and desired backup duration before ordering. Battery quantity, capacity, cabling and any external battery cabinet must be selected for the specified UPS model. An SNMP card is optional rather than included as standard.

Frequently Asked Questions
Which capacities are covered?

This single-phase listing covers 1, 2, 3, 6 and 10kVA CNER models, with rated real power from 0.8 to 8kW.

Does zero transfer time apply to every operating change?

No. Mains-to-battery transfer is 0ms. The catalog specifies inverter-to-bypass transfer of up to 4ms for 1–3kVA models and 0ms for 6–10kVA models.

How long will the UPS run during an outage?

Runtime depends on the selected battery configuration and connected load. Provide both values when requesting a configuration.

Are all units the same size?

No. Rack depth, height and weight vary by capacity and by standard or long-backup configuration. Use the selected model's dimensions.

Can the UPS be monitored remotely?

RS-232/USB communications are provided, and an optional SNMP card supports network management.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Coolnet power Co., ltd
Location High-tech Zone Mechanical and Electrical Industrial Park,Hefei City Anhui Province
Contact Person Janet Si

Request A Quote

Please check your email address.
Your message must be at least 20 characters.