Precision Cooling Units 60-102kW R22(R407C) Air Cooling Systems with 15000-25000 m3/h Airflow

Price Negotiable
Price: to be Negotiated
MOQ: 1
Delivery Time: 4W
Brand: Coolent
Product Description

Precision Cooling Units Air Cooling Systems For Switch Rooms And Mobile Computer Rooms

 

Products Introduction                                                

Coolnet precision air conditioner is different from ordinary household air conditioner, which is dedicated to computer room equipment. Due to the equipment in switch rooms and mobile computer rooms is composed of many electronic components and generates a lot of heat during operation, precision air conditioners are required to maintain the stability of the environment.

 

Advantages                                      

  • Integrated iFreecooling, saving 70% of energy consumption
  • 365X24 uninterrupted operation guarantee
  • Modular design concept
  • Matching multiple air supply modes on-site with upper air supply, lower air supply, EC fan sinking air supplyØ Inverter series air-cooled energy-saving air conditioners, saving 40% of energy consumption
  • Adapt to low load design

Main Components                                

Expansion Valve

Advanced thermal expansion valve has strong reliability and stability, and can accurately control the supply of refrigerant;

Advanced electronic expansion valve realizes energy saving and consumption reduction.

 

Humidifier

Advanced electrode steam humidification system, computer controlled humidification amount and water inlet and outlet;
The automatic cleaning procedure of the humidification cylinder ensures the normal humidification efficiency of the slag.

 

Scroll Compressor

The fully enclosed scroll compressor ensures the high efficiency, low noise and long life of the unit.

 

Applications                            

  • Switch room and mobile computer room
  • Computer room and data center (IDC)
  • High-tech environment and laboratory
  • Industrial control room and precision processing equipment
  • Standard testing room and calibration center
  • UPS and battery room
  • Biochemical culture room
  • Hospitals and testing rooms
 

Technical Parameters                                   

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180
 
Certificates                             
 
Factory Details                                   
 
Packing & Delivery                                             
 
Case                                                        
 
 
 

   

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Coolnet power Co., ltd
Location High-tech Zone Mechanical and Electrical Industrial Park,Hefei City Anhui Province
Contact Person Janet Si

Request A Quote

Please check your email address.
Your message must be at least 20 characters.