2 Way C13 12 Way C19 PDU With Master Switch and 60A Current for Rack Mount Power Distribution

Price Negotiable
Price: 50-500 USD per unit
MOQ: 1 unit
Delivery Time: 15 days
Brand: COOLNET
Product Description

2 Way C13 12 Way C19 PDU With Master Switch 

 

Product Introduction                                 

PDUs are often referred to as power distribution sockets for cabinets. PDUs are products designed to provide power distribution for electrical equipment installed in cabinets. They have various series of specifications with different functions, installation methods and different socket combinations. The power environment provides a suitable rack-mounted power distribution solution. When the socket becomes neccessary in the computer room, it cannot meet the needs of the environment. When the high-power equipment is everywhere, its operation is limited due to the socket. Messy and unsightly computer rooms would cause lots of hidden danger. Therefore, high quality PDU protection should be needed.

 

Technical Features                                       

 

1) Internal connection:
The connections between socket modules are all connected by screw terminals and plug-in terminals, and there are convenient devices such as fixing bolts for fixing cables at the ends of the sockets. The socket reed is phosphor bronze, with excellent contact and good elasticity, and can withstand more than 10,000 hot swaps;

 

2) Intelligence
easy management and remote control: optional additional functions such as digital display, abnormal alarm, network management, etc., highlight the intelligence of the product, improve its usability and manageability; security protection

 

3) Multiple circuit protection
lightning strike, surge protection: maximum impact current: 20KA or higher, limit voltage: less than or equal to 500V or lower.

 

Application                                               

  • Communication industry
  • Security system
  • IDC engine room
  • Electric power system
  • Track traffic
  • Enterprise small and medium data center
  • Office scene
  • Dispatch center
Horizontal Vertical  Intelligent Power Distribution Unit DC 48v 2

Parameter                                                  

 

PDU

 

Parameters

 

 

input

Input type AC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range 100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency 50/60Hz
total load current MAX 63A

 

 

Output

Storage temperature -40 - +70
Relative humidity 5-95% (No condensation)
Atmospheric pressure 70kPa - 106kPa
Working altitude No more than 4000M

 

 

Environmental

Working temperature -10 - +75
Storage temperature -40 - +80
Relative humidity 5-95% (No condensation)
Working altitude No more than 4000M
IP rating IP20
Protection input protection module Circuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection module Circuit breaker, fuse box, fuse(optional)

Installation method                                                   

Horizontal Vertical  Intelligent Power Distribution Unit DC 48v 3

 

Certification                                     

Horizontal Vertical  Intelligent Power Distribution Unit DC 48v 4

Case                                               

Horizontal Vertical  Intelligent Power Distribution Unit DC 48v 5

Factory                                           

Horizontal Vertical  Intelligent Power Distribution Unit DC 48v 6

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Coolnet power Co., ltd
Location High-tech Zone Mechanical and Electrical Industrial Park,Hefei City Anhui Province
Contact Person Janet Si

Request A Quote

Please check your email address.
Your message must be at least 20 characters.