1000V DC SPD 3P Suntree Surge Protector For Solar PV System
Suntree Surge Protector 3P 1000V DC SPD for Solar PV System
Installed in parallel on the DC networks to be protected and provide common and different modes protection.
High energy MOVs equipped with specific thermal disconnect
Related failure indicators.
With visual indication
With optional remote contact signaling
Adopt import high quality chip. Material Zinc oxide
Easy to change with plug-in module
Every pole achieve 1500V, 1200V, 1000V, 800V,500V
PPT cover with Anti flame material
Meet National Standard Test & TUV test
In accordance with IEC 60364-7-712
In 2 years warranty
Double protection: disconnection and short-shunting device with safe electrical isolation
Approved Static test: Voltage, current, leakage current
|
SUP2-PV series surge protector
|
SUP2-PV
|
|
|
||
|
Normal PV system voltage
|
1000V
|
1200V
|
1500V
|
||
|
MCOV
|
1170V DC
|
1200V DC
|
1500V DC
|
||
|
Max system discharge current
|
40ka
|
30ka
|
30ka
|
||
|
Voltage protection level
|
≤4kv
|
≤4.5kv
|
≤4.5kv
|
||
|
Voltage protection level at 5ka
|
≤3.5kv
|
≤4kv
|
≤4kv
|
||
|
Integrated Fuse breaking capacity
/interrupting rating |
30ka/100v dc
|
30ka/1200v dc
|
30ka/1500v dc
|
||
|
Technology
|
Short-current interription overload protection
|
|
|
||
|
Operating temperature range
|
-40℃ + 80℃
|
|
|
||
|
Normal discharge current
|
12.5ka
|
|
|
||
|
Response time
|
<25ns
|
|
|
||
|
Operating state/fault indication
|
green(good) Red(replace)
|
|
|
||
|
Conductor rating and cross-sectionalarea
|
Min: 60/75℃ 1.5mm2 /14AWG Solid/ Flexible
|
|
|
||
|
|
Max: 60/75℃ 35mm2 /2AWG Standards /25mm2/
|
|
|
||
|
Mounting
|
35mm din rail per EN 60175
|
|
|
||
|
Enclosure material
|
UL 94V0 thermoplactic
|
|
|
||
|
Degree of protection
|
IP20
|
|
|
||
|
Capacity
|
3 Modules, din 43880
|
|
|
||
|
Standards information
|
IEC 61643-11 Type2, IEC 61643-1 Class Ⅱ
|
|
|
||
|
Product warranty
|
Five years
|
|
|
||

The electrical circuit or communication lines because of outside interference peak current or voltage suddenly, the surge protector can in a very short time conducting shunt, so as to avoid damage to other equipment surge in the loop Installed front of inverter input and back of inverter output Installed in Parallel the spd is installed in the electric circuit with parallel, the first to play a protective role, the response time in the 25 to 50 nanosecond












Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.