Modbus Water Quality Transmitter 2 Alarm Relays Peracetic Acid Analyzer
2 Alarm Relays Peracetic Acid Analyzer Standard Modbus For Industrial Cooling Water
Product Introduction
Peracetic acid (C2H4O3) is a bright, colorless liquid that has a piercing odor and a low pH value. Peracetic acid is produced by a reaction between hydrogen peroxide and acetic acid. The DRFN’s peracetic acid analyzer ADS2-U3-P9.2 offers ease of use, accuracy and reliability for the monitoring and control of peracetic acid in water. The PAA analyzer consists of a transmitter and a peracetic acid probe.
Features Of The Transmitter
>> The peracetic acid controller is equipped with 2 settable 0/4~20mA active current loop outputs;
>> The standard configuration of the PAA transmitter is 2 settable SPST alarm relays;
>> Time and historical data recording functions to meet the user’s higher data management requirements;
>> Provide 100~240V AC or 18~36V DC power supply mode, both of which are wide-voltage power supply;
>> The communication standard is equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU;
Parameters Of Peracetic Acid Analyzer
| Product Name | Peracetic Acid Analyzer |
| Product Model |
ADS2-U3-P9.2 |
| Software Version |
DRFN peracetic acid Analysis software V1.0 |
| Display Range |
0.00~200.00mg/L |
|
Resolution |
0.001mg/L |
|
Accuracy |
Better than 0.15% of the measuring range |
|
Stability |
0.05% of the measuring range every 24 hours, no accumulation |
|
Repeatability |
Better than 0.1% of the measuring range |
|
Relay Control |
2 settable SPST relays, the max. load 3A/250VAC |
|
Sensor Self-diagnosis |
screen image and buzzer prompt |
|
Analog Current Output |
2 settable 0/4~20mA active current loop output max. load 1000Ω |
|
Communication Method |
MODBUS RTU; support JSON text data format |
|
Display Screen |
128*64 LCD |
|
Time History/Data Record |
Year/month/day/hour/min/second, record 14000 historical data |
|
Protection Grade |
IP66 |
|
Operating Environment |
0~60℃, relative humidity less than 95% |
|
Storage Environment |
-20~70℃, relative humidity less than 55% |
|
Shell Material |
Enhanced ABS |
|
Dimensions |
144*144*120mm (hole size 138*138 mm) |
|
Mounting Method |
Wall mounting, pipe clamping, panel installation |
|
Power Supply |
18~36V DC or 100~240V AC |
|
Weight |
800g |
| Power Consumption | 12W |
Matching Peracetic Acid Sensor Parameters
- Model: P9.2
- PH range: 1~6
- Pressure range: 0~1 bar, no pressure surges and/or fluctuations
- Temperature range: 0~60 ℃
- Response time: T90 about 3.5 min at 10 °C, about 45 s at 50 °C
- Flow rate: about 30 l/h, low flow-dependence
- Sensor with automatic temperature compensation
- Material: PEEK, stainless steel 1.4571
- Calibration: at the controller, analytical determination by DPD-method
- Application: Freshwater, all types of water treatment (surfactants and lead acids are tolerated).
| Type |
Measuring range: ppm |
Resolution: ppm |
Output signal | Power supply | Item number |
| P9.2-MA-200 | 0~200 | 0.1 | 4~20 mA |
12~30 VDC RL :50Ω~900Ω |
3426100 |
| P9.2-MA-2000 | 0~2000 | 1 | 3426101 | ||
| P9.2-MA-2% |
0~2 % (20000 ) |
0.001 % (10) | 3426102 | ||
| P9.2-MA-200-M12 | 0~200 | 0.1 | 4~20 mA |
12~30 VDC RL:50Ω~900Ω |
3426100 |
| P9.2-MA-2000-M12 | 0~2000 | 1 | 3426101 | ||
| P9.2-MA-2%-M12 |
0~2 % (20000 ) |
0.001 % (10) | 3426102 |