Suzhou Delfino Environmental Technology Co., Ltd.
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

Digital Online chlorine dioxide meter RS485 For Swimming Pools Disinfectant

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Brand: Daruifuno
Product Description

 

Digital Online Chlorine Dioxide Controller RS485 For Swimming Pools Disinfectant

 

 

Product Introduction

 

Chlorine dioxide disinfectant is an internationally recognized high-efficiency disinfectant. It is very safe and has no residual toxicity. With the widespread application of chlorine dioxide as a disinfectant, it is very important to detect and control its concentration. DRFN’s DUC2-CD-H chlorine dioxide controller is used for the measurement of chlorine dioxide. It is a digital meter, which can be connected to DRFN’s digital chlorine dioxide sensors.

 

 

Features Of The Chlorine Dioxide Controller

 

● RS485 interface, MODBUS RTU communication protocol

 

● Time and historical data recording function

 

● 128*64 large LCD screen, adjustable backlight mode

 

● Power-off protection configuration, parameters can be kept indefinitely

 

● A variety of installation methods: wall, pipe clamping, and panel installation

 

● 2 settable 0/4~20mA active current loop outputs

 

● Provide AC or DC power supply mode, both of which are wide-voltage power supply

 

 

Applications Of The Chlorine Dioxide Controller

 

●  Disinfection Systems

●  Cooling Towers

●  Water Treatment

 

 

Technical Parameters

 

Product Name

Chlorine Dioxide Controller

Product Model

DUC2-CD-H

Software Version

DRFN chlorine dioxide Analysis software V1.0

Display Range

0.01mg/L~100g/L

Resolution

0.01mg/L

Relay Control

2 settable SPST relays max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface; MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD, adjustable backlight mode, adjustable display rate

Time/Data Record

Year/month/day/hour/min/second, record 14000 historical data, record interval can be set between 1~999 minutes

Maintenance Records

Last 100 times

Protection Level

IP66

Operating Environment

0~60℃, relative humidity less than 95% (no condensation)

Storage Environment

-20~70℃, relative humidity less than 55% (no condensation)

Shell Material

Enhanced ABS

Size

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel mounting

Power Supply

18~36V DC or 100~240V AC

Weight

800g

Power Consumption

7W

 

 

 

The Suitable Chlorine Dioxide Sensors Recommendation

 

  • Model: AS2 AS3
  • pH range: 1~12
  • Pressure range: 0~8 bar

  • Temperature range: 0~50℃ (AS2), 0~70℃(AS3)
  • Automatic temperature compensation
  • Response time: T90 about 30 s
  • Flow rate: about 30 l/h
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U (AS2), PEEK (AS3)

Type:

(50℃)

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
AS2H-CD-M0c 0.005~2.00 0.001

Modbus RTU

9~30 V DC

20~56 mA

3426820
AS2N-CD-M0c 0.03~10.00 0.01 3426821

 

Type:

(70℃)

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
AS3H-CD-M0c 0.005~2.00 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426870
AS3N-CD-M0c 0.03~10.00 0.01 3426871

 


  • Model: CD4.2
  • pH range: 1~12
  • Pressure range: 0~1 bar

  • Temperature range: 0~45℃
  • Automatic temperature compensation
  • Response time: T90 about 15 s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, semipermeable membrane

Type

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number

CD4.2H-M0c

0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3326465

CD4.2N-M0c

0.05~20.00 0.01

3326466

 


  • Model: CD7
  • pH range: 1~11
  • Pressure range: 0~1 bar

  • Temperature range: 0~50℃
  • Automatic temperature compensation
  • Response time: T90 about 90 s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, stainless steel 1.4571, semipermeable membrane

 

Type

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number

CD7H-M0c

0.005~2.000

0.001

Modbus RTU

9~30 VD

20~56 mA

3226620

CD7N-M0c

0.05~20.00

0.01

3226621

CD7L-M0c

0.5~ 200.0

0.1

3226622

 


  • Model: CD10
  • pH range: 1~12
  • Pressure range: 0~1 bar

  • Temperature range: 0~50℃
  • Automatic temperature compensation
  • Response time: T90 about 60 s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, semipermeable membrane

 

Type

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
CD10H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 VD

20~56 mA

3426220

CD10N-M0c 0.05~20.00 0.01

3426221

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Suzhou Delfino Environmental Technology Co., Ltd.
Location Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
Contact Person Yuki Fu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.