Variable Frequency AC Resonant Test System High Voltage Test Set For UHV Substation Or GIS
Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or GIS
I. Application :
This series of test system mainly aims at AC voltage withstand test of primary equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only meet the requirements of voltage withstand of HV transformer, GIS, SF6 breakers,mutual inductions and bushings but also that of long distance XLPE cables ,with compatibility of extensive tests to be a desired voltage withstand test device for power supply system overhauling and electric power engineer construction units.
The above picture is for variable series resonance test system of 5000KVA/1000KV on test field in Shanxi Jindongnan Substation, testing HV
GIS of 1000KV class UHV line in domestic.
Applicable objects
- Long distance XLPE cables with 110KV,220KV,500KV class
- HV GIS or GIL, HV coupling capacitor,capacitor voltage transformer of no more than 1000KV class
- Assembling capacitor(test frequency pledges in 45—65Hz)
II. Main Components:(4000KVA/1000KV test system for example)
| SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension |
| 1 | Variable frequency power | FKVF-200kW/380V | 1piece | 180kgs | 750*700*1000mm |
| 2 | Excitation transformer | CQSB(J)-200kVA | 1piece | 1800kgs | 650*650*800mm |
| 3 | HV resonant test reactor | CHX(kf)-800kVA/200kV | 5pieces | 2800kgs | D1200*H1250mm |
| 4 | Capacitive divider | TRF-1000kV/1000pF | 1set | 550kgs | D350*H7600mm |
| 5 | Special test accessories | 1set |
Note:1.Load capacitantor can be optional when small load line is tesing or need analog load to control test frequency .
2.Test reactor can be produced to be 150KV,200KV,250KV,300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~15A optional in this serialized set,
3. HV Damping inductance can be optional for suppressing high frequency harmonics and resisting overvoltage caused from tested object flashover, special in EHV or UHV test set.
III. Test priciple :
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
IV. General Technical Data:
- Mode of system test: Series resonant with variable frequency
- System model : CHX-4000KVA/200KV,400KV,600KV, 800KV,1000KV
- Input power supply : 380±10%(three-phase),50Hz/60Hz
- Number of HV test reactor: 4pieces
- Rated output capacity: 4000kVA
- Rated output Voltage: 200KV,400KV,600KV,800KV,1000KV
- Max Test voltage : no more than 200KV,400KV,600KV,800KV,1000KV
- Rated output current: 4A /single piece or in series;16A or 20A in parallal
- Reg. Freq range : 20Hz-300Hz
- Output Resonance voltage waveform: sine wave
- THD of output waveform: ≤1%
- Insulation level: Under 1.1 times and keeping 1min, normal
- Duty cycle : 60mints optional on under rated current working condition ;
- Quality factor of test set itself: Q≥60
- Temperature rise: Less than 65K under rated current working withn duty cycle;
- Noise level: No more than 70B
- Reactor Structure: oil immersed type, epoxy tube cylinder type;
V. Technical Feature and advantage
- Modular design, being able for series-parallel connection of reactors,wide range of application.
- Operating frequency range:20-300Hz
- High quality factor value:Q ≥ 100(when f=20Hz) large thermal capacity, low temperature rise, long
- continuous of performance period
- Convenient for field test for the size and weight smaller than conventional test transformers.
- The output voltage waveform is sine wave, the waveform deviation factor ≤ 1%
- This device can be furnished with special test vehicle and container together
- PD free design optional.
VI. Main Measuring and control software panel as following :
VII.Accessories
- Accessory box for storage accessoires
- Input cables of power source
- Output cables of power source
- Output cables of exciting transformer
- System grounding cables
- Parallel cables of the reactor
- HV measuring cables ( the signal output cables of voltage divider )
- HV output cables(reactor to divide,divider to test object)
- Supporting base for divider
- Corona ring for test reactor and divider
- A final test report, a quality Certificate ,a user manual and a packing list are offered .
VIII. Other Typical Model
1 For 123KV ~300KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
| CHX-400KVA/200KV,400KV | 200KV*2 | 2A@200KV | 400KVA | For 123KV and below class GIS |
| 1A@400KV | For 300KV and below class GIS | |||
| CHX-800KVA/200KV,400KV | 200KV*2 | 4A@200KV | 800KVA | For 123KV and below class GIS |
| 2A@400KV | For 300KV and below class GIS | |||
| CHX-1000KVA/200KV,400KV | 200KV*2 | 5A@200KV | 1000KVA | For 123KV and below class GIS |
| 2.5A@400KV | For 300KV and below class GIS | |||
| CHX-2000KVA/200KV,400KV | 200KV*2 | 10A@200KV | 2000KVA | For 123KV and below class GIS |
| 5A@400KV | For 300KV and below class GIS | |||
| Special requirement can be made by order | ||||
2 For 145KV ~362KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
| CHX-500KVA/250KV,500KV | 250KV*2 | 2A@250KV | 500KVA | For 145KV and below class GIS |
| 1A@500KV | For 362KV and below class GIS | |||
| CHX-1000KVA/250KV,500KV | 250KV*2 | 4A@250KV | 1000KVA | For 145KV and below class GIS |
| 2A@500KV | For 362KV and below class GIS | |||
| CHX-2000KVA/250KV,500KV | 250KV*2 | 8A@250KV | 2000KVA | For 145KV and below class GIS |
| 4A@500KV | For 362KV and below class GIS | |||
| CHX-3000KVA/250KV,500KV | 250KV*2 | 12A@250KV | 3000KVA | For 145KV and below class GIS |
| 6A@500KV | For 362KV and below class GIS | |||
| Special requirement can be made by order | ||||
3 For 170KV ~550KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
| CHX-1200KVA/300KV,600KV | 300KV*2 | 4A@300KV | 1200KVA | For 170KV and below class GIS |
| 2A@600KV | For 550KV and below class GIS | |||
| CHX-1800KVA/300KV,600KV | 300KV*2 | 6A@300KV | 1800KVA | For 170KV and below class GIS |
| 3A@600KV | For 550KV and below class GIS | |||
| CHX-2400KVA/300KV,600KV | 300KV*2 | 8A@300KV | 2400KVA | For 170KV and below class GIS |
| 4A@600KV | For 550KV and below class GIS | |||
| CHX-3600KVA/300KV,600KV | 300KV*2 | 12A@300KV | 3600KVA | For 170KV and below class GIS |
| 6A@600KV | For 550KV and below class GIS | |||
| CHX-4800KVA/300KV,600KV | 300KV*2 | 16A@300KV | 4800KVA | For 170KV and below class GIS |
| 8A@600KV | For 550KV and below class GIS | |||
| Special requirement can be made by order | ||||
4 For 123KV ~800KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
| CHX-2400KVA/200KV×4 | 800KV | 12A@200KV | 2400KVA | For 123KV and below class GIS |
| 6A@400KV | For 300KV and below class GIS | |||
| 3A@600KV | For 550KV and below class GIS | |||
| 3A@800KV | For 800KV and below class GIS | |||
| CHX-3600KVA/200KV×4 | 800KV | 13A@200KV | 3600KVA | For 123KV and below class GIS |
| 9A@400KV | For 300KV and below class GIS | |||
| 4.5A@600KV | For 550KV and below class GIS | |||
| 4.5A@800KV | For 800KV and below class GIS | |||
| CHX-4800KVA/200KV×4 | 800KV | 24A@200KV | 4800KVA | For 123KV and below class GIS |
| 12A@400KV | For 300KV and below class GIS | |||
| 6A@600KV | For 550KV and below class GIS | |||
| 6A@800KV | For 800KV and below class GIS | |||
| Special requirement can be made by order | ||||
IX. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS