XLPE PVC Insulation 185 Sqmm 240 Sqmm Low Voltage Power Cable with 90°C Operating Temperature and 0.6/1.0KV Rating
Price:
Negotiable
MOQ:
1000M
Delivery Time:
1-15days
Brand:
Sanwu
Product Description
Product Overview
XLPE PVC Insulation 185 Sqmm 240 Sqmm LV Power Cable is designed for reliable power transmission and distribution in low voltage applications. This aluminum conductor cable features extruded cross-linked polyethylene insulation and high-density cross-linked polyethylene jacketing for superior performance.
Key Applications
Suitable for power transmission and distribution lines with rated voltage (U0/U) 0.6/1.0KV, specifically intended for underground systems operated at 600 volts or less.
Technical Specifications
- Maximum conductor temperature: 90°C during normal operation, 250°C during short circuit (maximum 5 seconds)
- Minimum installation temperature: 0°C
- Minimum bending radius: 12D (where D refers to cable diameter)
- Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
- UL 854 compliant with Type USE-2 listing when specified
Cable Construction
- Conductors: Class B compressed aluminum 1350-H19 meeting ASTM B231 or B786 requirements
- Insulation: Extruded black cross-linked polyethylene (XLPE)
- Jacket: Extruded high-density cross-linked polyethylene meeting ASTM D1248, Type III requirements
- Color coding: Phase conductor is black, neutral conductor is black with three extruded yellow stripes
Features & Benefits
- Insulation/jacket system provides high degree of protection against insulation damage
- Maximum conductor operating temperature of 90°C in wet or dry locations for NEC-compliant applications
- Suitable for non-code-complying installations with 90°C rating in wet or dry locations per ICEA specifications
Available Options
- Aluminum 1350-H16 conductor
- Copper conductors
- Alternative neutral identification methods
- CDC Combined Duct & Cable
- Reeless Package
- PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
- Type USE-2 per UL 44
Technical Data Tables
Single Core Cable Specifications
| Nominal Cross Section (mm²) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Conductor DC Resistance (Ω/km) | Test Voltage (kv/5min) | Cable Current in Air (A) | Cable Current in Soil (A) |
|---|---|---|---|---|---|---|---|---|
| 1×1.5 | 0.7 | 1.5 | 6 | 53 | ≤12.1 | 3.5 | 26/26 | 33/32 |
| 1×2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 |
| 1×4 | 0.7 | 1.5 | 7 | 87/64 | ≤4.61/≤7.41 | 3.5 | 44/35 | 56/42 |
| 1×6 | 0.7 | 1.5 | 7 | 110/73 | ≤3.08/≤4.61 | 3.5 | 56/45 | 70/54 |
Two Cores Cable Specifications
| Nominal Cross Section (mm²) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Conductor DC Resistance (Ω/km) | Test Voltage (kv/5min) | Cable Current in Air (A) | Cable Current in Soil (A) |
|---|---|---|---|---|---|---|---|---|
| 2×2.5 | 0.7 | 1.8 | 11.8 | 151/118 | ≤7.41/≤12.1 | 3.5 | 26/20 | 35/27 |
| 2×4 | 0.7 | 1.8 | 12.7 | 198/146 | ≤4.61/≤7.41 | 3.5 | 34/27 | 45/36 |
| 2×6 | 0.7 | 1.8 | 13.7 | 250/173 | ≤3.08/≤4.61 | 3.5 | 43/35 | 57/46 |
| 2×10 | 0.7 | 1.8 | 16.3 | 374/245 | ≤1.83/≤3.08 | 3.5 | 60/47 | 77/59 |
Three Cores Cable Specifications
| Nominal Cross Section (mm²) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Conductor DC Resistance (Ω/km) | Test Voltage (kv/5min) | Cable Current in Air (A) | Cable Current in Soil (A) |
|---|---|---|---|---|---|---|---|---|
| 3×1.5 | 0.7 | 1.5 | 10 | 145 | ≤12.1 | 3.5 | 20 | 27 |
| 3×1.6 | 0.7 | 1.5 | 11 | 185/140 | ≤7.41/≤12.1 | 3.5 | 26/20 | 35/27 |
| 3×4 | 0.7 | 1.5 | 12 | 250/175 | ≤4.61/≤7.41 | 3.5 | 34/27 | 45/36 |
| 3×6 | 0.7 | 1.5 | 13 | 320/210 | ≤3.08/≤4.61 | 3.5 | 43/35 | 57/46 |
| 3×10 | 0.7 | 1.5 | 15 | 450/260 | ≤1.83/≤3.08 | 3.5 | 60/47 | 77/59 |
Four Cores Cable Specifications
| Nominal Cross Section (mm²) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Conductor DC Resistance (Ω/km) | Test Voltage (kv/5min) | Cable Current in Air (A) | Cable Current in Soil (A) |
|---|---|---|---|---|---|---|---|---|
| 4×4 | 0.7 | 1.5 | 13 | 253/155 | ≤4.61/≤7.41 | 3.5 | 34/27 | 45/36 |
| 4×6 | 0.7 | 1.5 | 14 | 337/184 | ≤3.08/≤4.61 | 3.5 | 43/35 | 57/46 |
| 4×10 | 0.7 | 1.5 | 16 | 501/258 | ≤1.83/≤3.08 | 3.5 | 60/47 | 77/59 |
Related Videos