0.6/1kV All Aluminum Conductor ABC Power Cable with XLPE Insulation for Overhead Distribution
Price:
Get within 12 hours
MOQ:
1000M
Delivery Time:
1-15days
Brand:
Sanwu
Product Description
Product Overview
0.6/1kV overhead voltage power cable designed for 600V overhead auxiliary power distribution lines. Features 1350-H19 aluminum wire, 6201-T81 aluminum alloy or ACSR conductor construction with concentric stranded wire and polyethylene, high density polyethylene (HDPE) or cross-linked polyethylene (XLPE) insulation for weather protection.
Product Images
Technical Specifications
Primary Construction Details
| Rated Voltage | Specification | Structure |
|---|---|---|
| 0.6/1kV | ABC | AWG or kcmi configurations |
Detailed Configuration Table
| AWG/kcmil | Carrying Wire Core (ACSR) | Phase Conductor | Insulation |
|---|---|---|---|
| 3*6AWG+1*6AWG | Steel: 1×1.68mm, Aluminum: 6×1.68mm | Aluminum: 1×4.11mm | XLPE: 1.14mm |
| 3*6AWG+1*6AWG | Steel: 1×1.68mm, Aluminum: 6×1.68mm | Aluminum: 7×1.55mm | XLPE: 1.14mm |
| 3*4AWG+1*4AWG | Steel: 1×2.12mm, Aluminum: 6×2.12mm | Aluminum: 1×5.19mm | XLPE: 1.14mm |
| 3*4AWG+1*4AWG | Steel: 1×2.12mm, Aluminum: 6×2.12mm | Aluminum: 7×1.96mm | XLPE: 1.14mm |
| 3*2AWG+1*2AWG | Steel: 1×2.67mm, Aluminum: 6×2.67mm | Aluminum: 7×2.47mm | XLPE: 1.14mm |
Applications
- 120 volt aerial service for temporary construction sites
- Outdoor and street lighting installations
- 600 volt or lower service at conductor temperature of 75℃ maximum
Performance Specifications
| Nominal Cross Section | Neutral Core | Phase Core | Weight (kg/km) | Allowable Ampacity (A) |
|---|---|---|---|---|
| 1*6AWG+1*6AWG | 7×1.56mm | 1×4.11mm | 92 | XLPE: 85, PE: 70 |
| 1*6AWG+1*6AWG | 7×1.56mm | 7×1.56mm | 94 | XLPE: 85, PE: 70 |
| 1*4AWG+1*4AWG | 7×1.96mm | 1×5.19mm | 139 | XLPE: 115, PE: 90 |
| 1*4AWG+1*4AWG | 7×1.96mm | 7×1.96mm | 141 | XLPE: 115, PE: 90 |
Triplex Service Drop - Aluminum Conductor
Designed to supply power from utility lines to consumer weatherhead. For service at 600 volt or less (phase to phase) at conductor temperature of 75℃ maximum for polyethylene insulation or 90℃ maximum for crosslinked insulation.
Triplex Configuration Details
| AWG/kcmil | Bare Neutral Messenger | Phase Conductor | Weight (kg/km) | Allowable Ampacity (A) |
|---|---|---|---|---|
| 2*6AWG+1*6AWG | AAC: 7×1.56mm | AAC: 1×4.11mm | 146 | XLPE: 85, PE: 70 |
| 2*6AWG+1*6AWG | AAC: 7×1.56mm | AAC: 7×1.56mm | 150 | XLPE: 85, PE: 70 |
| 2*4AWG+1*4AWG | AAC: 7×1.96mm | AAC: 1×5.19mm | 219 | XLPE: 115, PE: 90 |
| 2*4AWG+1*4AWG | AAC: 7×1.96mm | AAC: 7×1.96mm | 224 | XLPE: 115, PE: 90 |
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Luoyang Sanwu Cable Co., Ltd.,
Location
Guobao Mansion 2110, Southwest Crossing of Kaiyuan Avenue and Wangcheng Avenue, Luoyang, China
Contact Person
Alex Yang