Product Description
200GPM Electrodeionization Water Purification System
The Electro-Deionization (EDI) process represents the latest technology in deionized water treatment for achieving ultrapure water quality. EDI utilizes ion exchange resins combined with a DC voltage potential to effectively remove cation and anion contaminants from feed water supplies.
Technology Overview
Ion selective membranes within the modules continuously remove contaminants and discharge them through a small concentrate stream. The applied voltage enables electrochemical water splitting into hydrogen (H+) and hydroxide (OH-) ions within the ion exchange resins, providing continuous regeneration without chemical additives, wastewater disposal requirements, or system shutdown time.
Key Advantages
- Chemical-free operation eliminates regeneration chemicals
- Continuous operation with no shutdown for regeneration
- Minimal wastewater generation compared to traditional systems
- Superior to conventional Mixed-Bed Deionization and Service Exchange DI Systems
Industrial Applications
- Power Generation
- Chemical Manufacturing
- Electronics / Semiconductor Production
- Industrial Process Water
- Boiler Feed Systems
- Research Laboratory Facilities
Operating Parameters
Nominal Recovery: 90-95%
EDI Water Quality: 15-18 meg-ohm
Operating Temperature: 50-100°F
Maximum Inlet Pressure: 100 psig
Minimum Inlet Pressure: 60 psig
Expected Pressure Drop: 30-40 psig
Electrical Requirements: 460 VAC, 3-phase, 60 Hz or 120 VAC, 1-phase, 60 Hz
EDI Water Quality: 15-18 meg-ohm
Operating Temperature: 50-100°F
Maximum Inlet Pressure: 100 psig
Minimum Inlet Pressure: 60 psig
Expected Pressure Drop: 30-40 psig
Electrical Requirements: 460 VAC, 3-phase, 60 Hz or 120 VAC, 1-phase, 60 Hz
Materials of Construction
Skid Frame: Epoxy-coated carbon steel
EDI Housings: FRP (Fiber Reinforced Plastic)
System Piping: Schedule 80 PVC
EDI Cell Tubing: Polyethylene
EDI Housings: FRP (Fiber Reinforced Plastic)
System Piping: Schedule 80 PVC
EDI Cell Tubing: Polyethylene
System Specifications
| MODEL | MEDI-25 | MEDI-50 | MEDI-100 | MEDI-150 | MEDI-200 |
|---|---|---|---|---|---|
| EDI Water Production Rate (GPM) | 25 | 50 | 100 | 150 | 200 |
| Quantity of EDI Cells | 1 | 2 | 4 | 6 | 8 |
| Maximum Current Load at 350 VDC (AMP) | 6 | 12 | 24 | 36 | 48 |
| Inlet Feed Water Rate (GPM) | 28 | 55 | 110 | 166 | 220 |
| Maximum Water to Drain (GPM) | 3 | 5 | 10 | 16 | 20 |
| System Dimensions (LxWxH) | 92"x48"x73" | 100"x48"x73" | 133"x48"x73" | 133"x48"x84" | 133"x48"x84" |
| Shipping Weight (LBS) | 2,200 | 2,500 | 3,000 | 3,750 | 4,400 |
Feedwater Requirements
| Parameters | Requirement |
|---|---|
| Feed Conductivity (including CO2) | < 10 µs/cm |
| pH | 7-10 |
| Silica (Reactive) | < 0.1 ppm |
| Total Hardness as CaCO3 | < 0.1 ppm |
| TOC | < 0.1 ppm |
| Heavy Metals (Fe, Mn etc.) | < 0.01 ppm |
| Free Chlorine as Cl2 | < 0.05 ppm |
Standard specifications are based on typical applications and incoming water quality from a Two-Pass Reverse Osmosis (RO) System. Specifications may be altered to meet certain site conditions and changes in incoming and/or product water quality requirements. Dimensions and shipping weights are estimated only. Actual dimensions and weights differ dependent upon the final system design and options selected.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Wuxi Fenigal Science & Technology Co., Ltd.
Location
606#, Building-B, Dicui Rd. 100, Binhu, Wuxi, Jiangsu, China
Contact Person
Joe Zu