Product Description
DuPont™ UF SFP-2880 High-Efficiency Filtration for Critical Water Applications
Product Overview
The DuPont™ UF SFP-2880 is an ultrafiltration membrane element utilizing a PVDF (polyvinylidene fluoride) hollow fiber structure. Designed for high-turbidity and highly contaminated water, it is suitable for demanding applications such as municipal wastewater reuse, industrial wastewater treatment, and food and beverage filtration. Leveraging DuPont's patented membrane technology, this product achieves industry-leading performance in terms of flux, fouling resistance, and service life.
Key Specifications
| Attribute | Value |
|---|---|
| Flow Range | 3.1 – 9.3 m³/hr |
| Membrane Area | 77 m² |
| Nominal Pore Diameter | 0.03 µm |
| Core Material | PVDF |
| Filtrate Flux | 40-120 |
| Diameter | 8 inch |
| Flow Direction | External pressure structure, dead end filtration |
| Max. Operating TMP | 2.1 bar |
| Max. Inlet Module Pressure | 6.25 bar |
| Operating pH Range | 2-11 |
| Certifications | ISO 9001, NSF, CE |
Typical Applications
- Brackish water desalination (groundwater, wells)
- Industrial process water (food & beverage, pharmaceuticals)
- Wastewater recovery & reuse (mining, textiles, electronics)
- Pre-treatment for ultrapure water (power plants, semiconductors)
Performance Advantages
30% lower energy consumption than comparable UF modules
3-5 year typical membrane lifespan with proper maintenance
Automated cleaning cycles maintain stable operation
NSF/ANSI 61 certified for drinking water applications
Product Specifications
| Model | Type | Part # | Membrane Area (m²) | Weight (kg) |
|---|---|---|---|---|
| SFP-2880 | Pretreatment | 280934 | 77 | 61/100 |
| SFD-2880 | NSF/ANSI 61 Drinking water | 324169 | 77 | 61/100 |
Operating Parameters
| Parameter | SI Units | US Units |
|---|---|---|
| Filtrate Flux @ 25ºC | 40-120 l/m²/hr | 24-70 gfd |
| Temperature Range | 1-40ºC | 34-104ºF |
| Max. Inlet Module Pressure | 6.25 bar | 93.75 psi |
| Max Operating Air Scour Flow | 12 nm³/hr | 7.1 scfm |
| Operating pH | 2-11 | |
Installation & Operation
Proper startup procedure is critical to prevent membrane damage and maintain system parameters within design specifications. Before startup:
- Complete membrane preconditioning and module installation
- Calibrate all instrumentation
- Flush the system thoroughly to eliminate shipping solution
- Purge residual air from the system
Note: Operating limits and guidelines must be strictly followed to maintain warranty coverage. Refer to the product technical manual for detailed instructions.