XLPE Insulation Industrial Electrical Cable, DJX Steal Tape Aromred 10 Gauge Electrical Cable

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 7-15 working days
Brand: DONGJIAXIN
Product Description

Copper Conductor XLPE Insulation DJX Steel Tape Aromred and PVC Jacket Flame Retardant Power Cable

Application:

    1kV for Fixed installations such as distribution networks or industrial installations.

Constraction:

Core Conductor annealed copper (stranded core)
Popular sizes 2~5 core x1.5~630mm²
Cable conductor stranded annealed copper
Insulation XLPE
Jacket pvc with steel tape aromred 
Temperature rating -25C up to +90℃
Voltage suitable 0.6/1kV
Fire performance IEC 60332-1
Approval QS in China

Advantage:

  Compressed Conductor easy for installation, UV - resistant , Exellent in physical protection

Standards&Certificates:

     IEC 60502-1

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 2×0.14 0.7 1.4 6.0 12.1
1×2.5 1 2×0.14 0.7 1.4 6.4 7.41
1×4 1 2×0.14 0.7 1.4 6.9 4.61
1×6 1 2×0.14 0.7 1.4 7.3 3.08
1×10 7 2×0.14 0.7 1.4 8.4 1.83
1×16 7 2×0.14 0.7 1.4 9.4 1.15
1×25 7 2×0.14 0.9 1.4 11.0 0.727
1×35 7 2×0.14 0.9 1.4 12.0 0.524
1×50 10 2×0.14 1.0 1.4 13.3 0.387
1×70 14 2×0.14 1.1 1.4 15.1 0.268
1×95 19 2×0.14 1.1 1.5 17.3 0.193
1×120 24 2×0.14 1.2 1.5 19.0 0.153
1×150 30 2×0.14 1.4 1.6 20.9 0.124
1×185 37 2×0.14 1.6 1.6 23.0 0.0991
1×240 48 2×0.14 1.7 1.7 25.7 0.0754
1×300 61 2×0.14 1.8 1.8 28.3 0.0601
1×400 61 2×0.14 2.0 1.9 31.6 0.0470
1×500 61 2×0.14 2.2 2.0 35.1 0.0366
1×630 61 2×0.14 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 2×0.14 0.7 1.8 10.6 12.1
2×2.5 1 2×0.14 0.7 1.8 11.4 7.41
2×4 1 2×0.14 0.7 1.8 12.4 4.61
2×6 1 2×0.14 0.7 1.8 13.2 3.08
2×10 7 2×0.14 0.7 1.8 15.4 1.83
2×16 7 2×0.14 0.7 1.8 17.4 1.15
2×25 7 2×0.14 0.9 1.8 20.6 0.727
2×35 7 2×0.14 0.9 1.8 22.6 0.524
2×50 10 2×0.14 1.0 1.8 26.2 0.387
2×70 14 2×0.14 1.1 1.8 29.8 0.268
2×95 19 2×0.14 1.1 1.9 34.0 0.193
2×120 24 2×0.14 1.2 2.0 37.4 0.153
2×150 30 2×0.14 1.4 2.2 41.2 0.124
2×185 37 2×0.14 1.6 2.3 45.6 0.0991
2×240 48 2×0.14 1.7 2.5 51.0 0.0754
2×300 61 2×0.14 1.8 2.6 56.0 0.0601
2×400 61 2×0.14 2.0 2.9 62.6 0.0470
2×500 61 2×0.14 2.2 3.1 70.0 0.0366
2×630 61 2×0.14 2.4 3.3 83.6 0.0283
3×1.5 1 2×0.14 0.7 1.8 11.2 12.1
3×2.5 1 2×0.14 0.7 1.8 12.1 7.41
3×4 1 2×0.14 0.7 1.8 13.2 4.61
3×6 1 2×0.14 0.7 1.8 14.0 3.08
3×10 7 2×0.14 0.7 1.8 16.4 1.83
3×16 7 2×0.14 0.7 1.8 18.6 1.15
3×25 7 2×0.14 0.9 1.8 22.0 0.727
3×35 7 2×0.14 0.9 1.8 24.2 0.524
3×50 10 2×0.14 1.0 1.8 28.0 0.387
3×70 14 2×0.14 1.1 1.9 32.1 0.268
3×95 19 2×0.14 1.1 2.0 36.4 0.193
3×120 24 2×0.14 1.2 2.1 40.3 0.153
3×150 30 2×0.14 1.4 2.3 44.3 0.124
3×185 37 2×0.14 1.6 2.4 49.1 0.0991
3×240 48 2×0.14 1.7 2.6 54.9 0.0754
3×300 61 2×0.14 1.8 2.7 60.1 0.0601
3×400 61 2×0.14 2.0 3.0 67.4 0.0470
3×500 61 2×0.14 2.2 3.2 75.3 0.0366
3×630 61 2×0.14 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 2×0.14 0.7 1.8 12.2 12.1
4×2.5 1 2×0.14 0.7 1.8 13.1 7.41
4×4 1 2×0.14 0.7 1.8 14.3 4.61
4×6 1 2×0.14 0.7 1.8 15.3 3.08
4×10 7 2×0.14 0.7 1.8 18.0 1.83
4×16 7 2×0.14 0.7 1.8 20.4 1.15
4×25 7 2×0.14 0.9 1.8 24.3 0.727
4×35 7 2×0.14 0.9 1.8 26.7 0.524
4×50 10 2×0.14 1.0 1.8 30.8 0.387
4×70 14 2×0.14 1.1 2.0 35.4 0.268
4×95 19 2×0.14 1.1 2.1 40.4 0.193
4×120 24 2×0.14 1.2 2.3 44.9 0.153
4×150 30 2×0.14 1.4 2.4 49.3 0.124
4×185 37 2×0.14 1.6 2.6 54.7 0.0991
4×240 48 2×0.14 1.7 2.8 61.0 0.0754
4×300 61 2×0.14 1.8 3.0 67.2 0.0601
4×400 61 2×0.14 2.0 3.3 75.3 0.0470
4×500 61 2×0.14 2.2 3.5 84.0 0.0366
4×630 61 2×0.14 2.4 3.8 100.5 0.0283
5×1.5 1 2×0.14 0.7 1.8 13.2 12.1
5×2.5 1 2×0.14 0.7 1.8 14.2 7.41
5×4 1 2×0.14 0.7 1.8 15.6 4.61
5×6 1 2×0.14 0.7 1.8 16.7 3.08
5×10 7 2×0.14 0.7 1.8 19.6 1.83
5×16 7 2×0.14 0.7 1.8 22.3 1.15
5×25 7 2×0.14 0.9 1.8 26.7 0.727
5×35 7 2×0.14 0.9 1.8 29.4 0.524
5×50 10 2×0.14 1.0 1.9 34.1 0.387
5×70 14 2×0.14 1.1 2.1 39.1 0.268
5×95 19 2×0.14 1.1 2.2 44.7 0.193
5×120 24 2×0.14 1.2 2.4 49.7 0.153
5×150 30 2×0.14 1.4 2.6 54.7 0.124
5×185 37 2×0.14 1.6 2.8 60.6 0.0991
5×240 48 2×0.14 1.7 3.0 67.7 0.0754
5×300 61 2×0.14 1.8 3.2 74.6 0.0601
5×400 61 2×0.14 2.0 3.5 83.4 0.0470
5×500 61 2×0.14 2.2 3.8 93.4 0.0366

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 2×0.14 0.7 1.8 12.9 7.41
3×4+1×2.5 1 2×0.14 0.7 1.8 14.0 4.61
3×6+1×4 1 2×0.14 0.7 1.8 15.1 3.08
3×10+1×6 7 2×0.14 0.7 1.8 17.3 1.83
3×16+1×10 7 2×0.14 0.7 1.8 19.8 1.15
3×25+1×16 7 2×0.14 0.9 1.8 23.3 0.727
3×35+1×16 7 2×0.14 0.9 1.8 25.1 0.524
3×50+1×25 10 2×0.14 1.0 1.8 29.4 0.387
3×70+1×35 14 2×0.14 1.1 1.9 33.5 0.268
3×95+1×50 19 2×0.14 1.1 2.1 38.1 0.193
3×120+1×70 24 2×0.14 1.2 2.2 42.5 0.153
3×150+1×70 30 2×0.14 1.4 2.3 45.8 0.124
3×185+1×95 37 2×0.14 1.6 2.5 51.2 0.0991
3×240+1×120 48 2×0.14 1.7 2.6 57.0 0.0754
3×300+1×150 61 2×0.14 1.8 2.8 62.6 0.0601
3×400+1×185 61 2×0.14 2.0 3.1 70.1 0.0470
3×500+1×240 61 2×0.14 2.2 3.3 78.3 0.0366
3×630+1×300 61 2×0.14 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 2×0.14 0.7 1.8 13.8 7.41
3×4+2×2.5 1 2×0.14 0.7 1.8 15.1 4.61
3×6+2×4 1 2×0.14 0.7 1.8 16.2 3.08
3×10+2×6 7 2×0.14 0.7 1.8 18.5 1.83
3×16+2×10 7 2×0.14 0.7 1.8 21.3 1.15
3×25+2×16 7 2×0.14 0.9 1.8 24.9 0.727
3×35+2×16 7 2×0.14 0.9 1.8 26.6 0.524
3×50+2×25 10 2×0.14 1.0 1.8 31.4 0.387
3×70+2×35 14 2×0.14 1.1 2.0 35.6 0.268
3×95+2×50 19 2×0.14 1.1 2.1 40.4 0.193
3×120+2×70 24 2×0.14 1.2 2.3 45.5 0.153
3×150+2×70 30 2×0.14 1.4 2.4 48.5 0.124
3×185+2×95 37 2×0.14 1.6 2.5 54.2 0.0991
3×240+2×120 48 2×0.14 1.7 2.7 60.3 0.0754
3×300+2×150 61 2×0.14 1.8 2.9 66.5 0.0601
3×400+2×185 61 2×0.14 2.0 3.2 74.3 0.0470
3×500+2×240 61 2×0.14 2.2 3.5 83.1 0.0366
3×630+2×300 61 2×0.14 2.4 3.8 97.0 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 2×0.14 0.7 1.8 14.0 7.41
4×4+1×2.5 1 2×0.14 0.7 1.8 15.3 4.61
4×6+1×4 1 2×0.14 0.7 1.8 16.5 3.08
4×10+1×6 7 2×0.14 0.7 1.8 19.1 1.83
4×16+1×10 7 2×0.14 0.7 1.8 21.8 1.15
4×25+1×16 7 2×0.14 0.9 1.8 25.8 0.727
4×35+1×16 7 2×0.14 0.9 1.8 28.0 0.524
4×50+1×25 10 2×0.14 1.0 1.9 32.8 0.387
4×70+1×35 14 2×0.14 1.1 2.0 37.3 0.268
4×95+1×50 19 2×0.14 1.1 2.2 42.7 0.193
4×120+1×70 24 2×0.14 1.2 2.3 47.5 0.153
4×150+1×70 30 2×0.14 1.4 2.5 51.6 0.124
4×185+1×95 37 2×0.14 1.6 2.6 57.4 0.0991
4×240+1×120 48 2×0.14 1.7 2.9 64.1 0.0754
4×300+1×150 61 2×0.14 1.8 3.1 70.6 0.0601
4×400+1×185 61 2×0.14 2.0 3.4 78.9 0.0470
4×500+1×240 61 2×0.14 2.2 3.6 88.2 0.0366
4×630+1×300 61 2×0.14 2.4 3.9 104.3 0.0283
 

 

Keywords: #Armouredcable #Armoredcable #cable #wire #electricalcable #DJXcable #Jiaxincable #AWGcable #PVCcable #XLPEcable

 

Company information:

35 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 100,000 square meters.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Location No.8 Huamei Road, Songgang Sub-District, Bao'an District, Shenzhen, Guangdong 518105, China
Contact Person Coco

Request A Quote

Please check your email address.
Your message must be at least 20 characters.