Product Description

Air Source Heat Pump Hot Water Type

Technical paramater:

Air source heat pump MODEL Unit MD40D
Average heating input power KW 3.78
Rated heating capacity KW 15
Hot water supply L/h 350
Rated heating input current A 9
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 55
Pipe size DN 25
Air source heat pump MODEL Unit MD50D
Average heating input power KW 4.6
Rated heating capacity KW 18.6
Hot water supply L/h 400
Rated heating input current A 9
Max outlet water temp C 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 170
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Article Parameter
Air source heat pump MODEL Unit MD60D
Average heating input power KW 5.2
Rated heating capacity KW 21
Hot water supply L/h 500
Rated heating input current A 12
Max outlet water temp 60
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 180
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000L/h
Water pressure down Kpa 48
Pipe size DN 25
Air source heat pump MODEL Unit MD100D
Average heating input power KW 9.2
Rated heating capacity KW 36
Hot water supply L/h 800
Rated heating input current A 18
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 310
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Air source heat pump MODEL Unit MD150D
Average heating input power KW 11
Rated heating capacity KW 42
Hot water supply L/h 1000
Rated heating input current A 24
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 340
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 12000L/h
Water pressure down Kpa 54
Pipe size DN 32
Article Parameter
Air source heat pump MODEL Unit MD200D
Average heating input power KW 19
Rated heating capacity KW 72
Hot water supply L/h 1600
Rated heating input current A 35
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Air source heat pump MODEL Unit MD300D
Average heating input power KW 22
Rated heating capacity KW 84
Hot water supply L/h 2000
Rated heating input current A 40
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 750
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 25000L/h
Water pressure down Kpa 60
Pipe size DN 50

 

Spare parts:

Heat exchanger type A: fin heat exchanger
Heat exchanger type B: coil heat exchanger
Heat exchanger type C: plate heat exchanger
Electric expansion valve
Expansion valve
Relay
Senssor connector
Liquid, gas separator
Sensor
Thermal expansion valve
Control panel

 

 

 Simple installation diagram for air source:

 

Our factory:

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Shenglin M&E Technology Co., Ltd.
Location Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Contact Person Jason

Request A Quote

Please check your email address.
Your message must be at least 20 characters.