Shanghai Shenglin M&E Technology Co., Ltd.
                                                                                                           
Verified Supplier
17 Years
Since 2009
Menu
Home Appliance Water Heaters Heat Pump Water Heaters

COP5.4 Swimming Pool Inverter Heat Pump 90kW Air Source Central Heating

Price Negotiable
Price: 1100~7300USD
MOQ: 1 pcs
Delivery Time: 18~20 days
Brand: Shenglin
Product Description

Air To Water Heat Pump For Swimming Pool


Features:


PVC Titaninm tube heat exchanger will full resistance against corrosion, more durable. Compact structure, easy demountable for access. High efficiency compressor, saving energy. Flow switch for water flow protection. Intelligent controller and adjustment by quick mind microprocessor. Intelligent LCD display wired controller. Air heat exchanger(fins-coil) with hydrophilic coating. Automatically defrosting function included.

Optional:

Galvanized metal cabinet or stainless steel cabinet.
Refrigerant: R22, R407C and R410A is available
Titaninm tube heat exchanger/stainless steel heat exchanger.


Technical paramater:

 

Commercial Swimming Pool Heat Pump
MODEL KFXY-010UMI KFXY-018UMII KFXY-023UMII KFXY-036UMII KFXY-045UMII KFXY-070UMII KFXY-090UMII
Heating mode / Circulating Circulating Circulating Circulating Circulating Circulating Circulating
Ambient temp. range -15~+43℃ -15~+43℃ -15~+43℃ -15~+43℃ -15~+43℃ -15~+43℃ -15~+43℃
Rated heating capacity KW 11 19 23 38 45 70 90
COP W/W 5.2 5.2 5.4 5.2 5.4 5.2 5.4
Rated power input KW 2.12 3.65 4.25 7.31 8.3 13.46 16.7
Max. running current A 10 13 14.5 13.06 26 50 48
Power supply / 220V/50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz
IP code / IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Safety function / High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc. High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.
Refrigerant type -/kg R410a/1.4 R410a/2.7 R410a/3.0 R410a/2.5×2 R410a/3.0×2 R410a/5×2 R410a/7.5×2
Compressor QTY PCS 1 1 1 2 2 2 2
Compressor type / Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Max. temp. outlet water 40 40 40 40 40 40 40
Water side heat exchanger type / Titanium tube heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger
Air side heat exchanger type / Finned heat exchanger Finned heat exchanger Finned heat exchanger Finned heat exchanger Finned heat exchanger Finned heat exchanger Finned heat exchanger
Circulating waterpipe nozzle inch G1'' G1.5'' G1.5'' G1.5'' G1.5'' G2'' G2''
Outlet nozzle inch G1'' G1.5'' G1.5'' G1.5'' G1.5'' G2'' G2''
Circulating water volume m3/h 4.73 8.17 9.89   19   39
Air out type / Vertical Vertical Vertical Vertical Vertical Vertical Vertical
Fan motor QTY PCS 1 1 1 2 2 3 2
Noise dB/(A) 56 56 56 59 68 68 69
Machine dimension (WxDxH) mm 750×690×870 750×690×1070 820×790×1080 1500×690×1070 1500×690×1380 2095×1005×1855 2095×1005×1855
Packing Dimension (WxDxH) mm 800×740×1000 800×740×1200 920×840×1210 1580×800×1200 1580×740×1550 2195×1105×1955 2195×1105×1955
Net Weight kg 110 130 150 230 330 700 800
Gross Weight kg 130 160 170 260 360 750 850
Remarks:
1. Test conditions: (DB/WB)20℃/15℃,inlet water temperature 26°C, outlet water temperature 28°C.
2. Due to product improvement, above datas are subject to change without priop notice, please take the rating plate as standard
3. This water heat pump system is only suitable for city water that meets the national standard, such as ground water, well water, etc., which is not covered by the warranty. If the water quality is poor, please install a filter and water processor.

 

Application:

Packing:

 


 

 

Reference:

 

Country: Taiwan,China, middle school
Model: KFXR-018 UII,KFXR-045UII
Application: Domestic hot water
Country: Taiwan,China,residential building
Model: KFXR-036UII,KFXR-900UII
Application: Domestic hot water
Country: Beijing, China
Model: KFXF-180 UII
Application: Breeding heating
Country: Yunan, China
Model: /
Application: Aloe drying

 

 

Schematic diagram:


 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Shenglin M&E Technology Co., Ltd.
Location Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Contact Person Jason

Request A Quote

Please check your email address.
Your message must be at least 20 characters.